SMC Corporation of America
Elite Part Number Search
Search Results "PFM511-02-2-A-R"

BBA2: D-A7/A8/F7/J7 The above stainless steel screw kit is used for auto switch D-F7BAL and D-F7BAVL when it is shipped mounted on a cylinder. Also, BBA2 is included when a auto switch alone is shipped. 3 Plate Cylinder with Lock Series MLU Construction !4 !7 !0 !4 @1 u q !3 !2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !

21.7 20 79.1 22 40.4 1 Reference dimensions 6 AS Series Dimensions DIN Rail Mounting Bracket L-Bracket Bracket on a single side Bracket on a single side AS1002F AS2002F L17 L16 L15 L12 L13 L14 L23 L22 L24 L11 t1 t2 2 x D5 2 x D6 L21 L20 L19 L10 L9 L18 L25 AS2052F AS3002F AS4002F L23 L22 L24 2 x D6 L21 L20 L19 L18 Part no.

Oooosite side of 02 2 stations 20 20 stations Same side as A port Port size I B3T lone touch frttina fors/32'tube B7T lone touch fittino for 1/4" tube Body ported / Type 21 (A pon: top porting) NW3KF3-21-@-OOT Applicable valves NVKF3330 OOO -M5 NVKF333O OOO -o1T .

Normally open Normally closed Polycarbonate AD52 -A AD51 -A Nylon AD52 -6-A AD51 -6-A Metal AD52 -2-A AD51 -2-A 1 Enter the piping thread type to of the bowl assembly part number. Nil: Rc thread, N: NPT thread, F: G thread Please consult with SMC separately for psi and F unit display spccifications.

Rod end nuts are included. 2 Series MTS Construction Basic type 8 !9 y !7 q e @0 !0 o @2 @3 !5 u t !8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No.

2, and the poppet valve piston !2 moves upward and stops when it is in contact with the main air supply adjustment nut t. The movement of the poppet valve piston !2 causes the connected poppet valve i to move further from the initial air supply adjustment position, and a greater volume of gas flows to the OUT (2) port.

Manifold Specifications Manifold Manifold type Number of valves Blanking plate (with gasket, screws) B Mount Common supply, Common exhaust, Individual out 2 to 10 stations VVX31 VX011-004 VX011-005 VVX32/33 JIS Symbol Port A Port A Port P Manifold Base and Applicable Solenoid Valve Part No. n: stations Port R Manifold base A port Applicable solenoid valve Base weight (g) VVX311-stations VVX312

Port size With One-touch fitting 01 M5 M5 R 1/8 R 1/4 R 3/8 R 1/2 02 03 04 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F02 (G1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -