Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 140 210 Pressure 0.7MPa Pressure 0.7MPa 120 180 0.6MPa 0.6MPa 100 Gripping force N Gripping force N 150 0.5MPa 0.5MPa 80 120 0.4MPa 0.4MPa 60 90 0.3MPa 0.3MPa 40 0.2MPa 60 0.2MPa 20 30 100 0 80 60 40 20 0 80 60 40 20 100 Gripping point L mm Gripping point L mm 12-3-5 6 Series MHF2 Model Selection Effective Gripping Force: Series MHF2
M1 0Xl.5 15 50 131 20 28 22 SO.6 44 B " M l 0)(1.5 M10)(I .S 63 138. 5 18 124 .5 SO.6 44 I. 8 Ml0Xl .5 15 20 30 22 " M12xl .75 M1 2x 1.75 lB 150 27 M1 6X2.0 21 80 168 22 38 28 64 56 18 10 10 0SM:: Series CDQ2BP High Magll8lic Field Resistance ," , [).P70 ' , D-~i4,,;'; ' ; ::~::Y_iidiz!C:::i Auto SWitch No.
MPa 0.20.6 0.10.6 -1060 mm 0.01 c.p.m. 120 60 30 9 21 36 62 97 155 280 400 1 N 16 28 47 82 130 204 359 525 mm 4 4 6 8 8 12 16 20 g 95 150 230 440 620 1,050 1,800 3,200 1) 1625 =20mm 3263 =30mm 80 =50mm 0.5MPa MHSH3 16D MHSH320D MHSH325D MHSH332D MHSH340D MHSH350D MHSH363D MHSH3MHSH380D mm 16 20 25 32 40 50 63 80 MPa 0.20.6 0.10.6 -1060 mm 0.01 c.p.m. 120 60 30 9 21 36 62 97 155
or less 70 or less 80 or less 70 or less 80 or less 80 or less Single 2-position 5 (R1) 3 (R2) Double 1 (P) N.C.
(at 80 mA load current) PNP: 1.5 V max.
C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.
Note 1) Please consult with SMC if other specifications for surface treatment are required. 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Laser marking Hexagon wrench 8-18-2 8-18-3 3 Series CYV Model Selection 1 Caution on Design (1) The allowable load mass moment differs depending on the workpiece mounting method, cylinder mounting orientation and
fluid temperature 2-position single, double 4-position dual 3 port valve 5 Max. operating frequency (Hz) 3-position 3 Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type Manual override (Manual operation) Pilot exhaust method Main/Pilot valve common exhaust Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s2) Note) 150
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
Only air, N2, are applicable. [6000] 6000 L/min (PF3A712H) [F 1] [ 150] 150 L/min (PF3A703H) The accumulated flow has exceeded the accumulated flow range. (For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Piston speed (3) 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage MQQ M 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Supply pressure 0.3 MPa 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa RHC Note 1) Use clean, dry air with no freezing.
150 With auto switch CA1 Number of auto switches S n Bore size 20mm 25mm 32mm 40mm CS1 Air cylinder with auto switch 20 25 32 40 2 1 n Without auto switch (Built-in magnet) Auto switch * Refer to the left table for selecting applicable auto switches.
100 27 54 85 2.5 6 12 25 50 75 125 125 150 190 2.65 3.88 6 8.48 10.59 0.35 0.88 1.77 3.53 7.06 10.59 17.66 21.19 26.49 35.31 Comes with pre-filter mist separator AFM, and micro mist separator AFD.
Impact acceleration [m/s] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Features 1 in vacuum environments (1.3 x 10-Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
Supplv Pressure 220 PSIG (15 Kqflcmz) Operating Pressure 22-150 PS|G (1.5-9.9 Kqf/cm2) 15-150 PS|G (1-9.9 Kqf/cm2) Ooeratino TemDerature 40-140'F (5-60'C) Bodv Aluminum Die Cast Spool & Sleeve 440F Stainless Steel, passivated & heat treated to 58-63 Rockwell C. Sleeve O-Rinqs Buna N Soacer Delrin Shock Pad Urethane Rubber Max. Cycle Rate 300 cPM Weight (Valve Body Only) oz.
Performance Data S Series Swivel (1/4", 3/8", 1/2", 3/4") Test Fluid: Oil 150 SUS vs. Pressure Drop 40 35 3/8" Features 3/4" 1/2" 30 3000 psi working pressure rating for all sizes. D Swivels Pressure Drop in PSID Variety of seal options. 25 Torque value does not significantly increase with pressure.
No Initial value Recommended value Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 65536 32768 65536 32768 65536 32768 Electronic gear denominator *3 PA07 1 150 75 75 150 75 75 250 125 125 200 100 50 Regenerative option PA02 0 0 (Non)/ 0002 (LEC-MR-RB-032) 1 1 0 0 Rotation direction selection *4 PA14 0 (+Counter (+Counter (+Counter (+Counter
For a longer reset input time, the processing time takes approximately 150 ms from startup of the reset signal, and this will increase the total reset processing time. If the table moves before the counter reset process is complete, the display value of the multicounter may be shifted.
Pneumatic Actuation Pressure Regulator Low flow Series AP10PA Actuation control pressure isolated from process gas by two seals Body material: 316L SS secondary remelt High inlet pressure type: Max. 3500 psig (24.1 MPa) Flow capacity Standard: to 30 slpm HF (Option): to 120 slpm Ni-Cr-Mo alloy internals available for corrosion resistance 100 psig (0.69 MPa) outlet pressure achievable with 80