SMC Corporation of America
Elite Part Number Search
Search Results "RZQD63-150-95"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 95, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 95, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 95, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

AMD LLB4-1-PRVSF AMH V2 AME 72.1 Mounting hole for 4 x M5 AMF ZFC 58 70 SF 1 A Valve open and locked position 508 10 10 SFD 95 (Lever operating direction) Max. 132 Connection part Rc 3/8 (NPT 3/8) LLB LLB A Hand valve Valve closed position AD Air operated valve 3.5 GD Clean regulator With flow adjuster Pressure outlet port Rc 1/8 One-touch fitting 12 Digital flow switch PA pilot port Rc 1

Branch Pipe: LMD Series How to Order LMD 1 2 Branch pipe No. of mixing valves 1 2 3 4 5 6 1 2 3 4 5 6 Air blow circuit 1 2 Available LMD1 LMD2 Not available Dimensions LMD1 n: Stations L 58 94 130 166 202 238 L1 44 80 116 152 188 224 Model LMD1-1 LMD1-2 LMD1-3 LMD1-4 LMD1-5 LMD1-6 n 3 6 9 12 15 18 L1 4 x 5.5 3 x Rc1/8 n = Rc 1/8 LMD2 n: Stations L1 25.5 44.5 63.5 82.5 101.5 120.5 L 38 57 76 95

240VAC Minimum inlet temperature 35F Maximum inlet temperature 122F Minimum ambient temperature 41F IDW4N-IDW35N IDW45N-IDW365N Purge rate 20% IDW04N-IDW175N IDW215N-IDW365N Dryer correction factors Operating pressure (psig) 58 72 87 100 116 130 145 160 174 189 203 218 232 Pressure correction factor (PCF)* 0.62 0.75 0.87 1 1.12 1.25 1.37 1.5 1.62 1.75 1.87 2.0 2.12 Temperature (F) 68 77 86 95

FGF FGH FGH [Test conditions] Fluid: water / Test dust: ACFTD / Flow rate: 35 L/min Dust concentration: 10 mg/L / Temperature: 20C Element: EJ801S Schematic diagram of filtration efficiency data measuring circuit FQ1 EJ-2 m FN 100 99 Dust feeder Initial filtration efficiency (%) EJ-4 m EB ES Tank Flow meter EJ-6 m Differential pressure gauge EJ-13 m 95 Pressure gauge Downstream side sampling

AF60-A 142.1 174.1 176.1 247.1 261.1 93.9 122.1 154.1 156.1 227.1 241.1 91.4 28 30 35 34 47 47 2.3 2.3 2.3 2.3 3.2 3.2 40 53 70 70 90 90 8.4 13 12.5 12.5 13 13 5.4 6.5 8.5 8.5 11 11 22 23 26 25 35 35 27 35 52 52 66 66 30 41 50 50 70 70 20 26.7 35.5 35.5 45 47.5 25 35 40 40 30 30 30 38.4 38.4 20 26.7 35.5 35.5 45 47.5 9.8 14 18 20 24 24 91.4 121.9 153.9 155.9 226.9 240.9 40 53 70 75 90 95

AS421F-U04-12 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 7.8 8.9 11.0 15.2 18.5 8.9 11.0 15.2 18.5 11.0 15.2 18.5 20.9 11.0 15.2 18.5 20.9 18.5 21.7 20.8 21.1 22.5 25.3 33.1 23.3 23.9 27.2 35.3 26.4 29.5 31.8 32.8 26.4 29.5 31.8 32.8 33.6 35.2 27.9 28.2 29.6 32.4 40.2 32.5 33.1 36.4 44.5 37.9 41.0 43.3 44.3 37.9 41.0 43.3 44.3 47.9 49.5 17 17 17 19 21 32 32 34 36 53 55 57 59 53 55 57 59 94 95

Preparation Filter AFF/AM/AMD Series Mist Separator AM Series Standard Specifications Model AM70D AM80D AM90D Fluid Compressed air Operating pressure range [MPa] 0.1 to 1.0 Ambient and fluid temperatures [C] 5 to 60 (No freezing) Proof pressure [MPa] 1.5 Maximum flow capacity*1 [m3/min (ANR)] 7.0 11.0 14.5 Inlet pressure [MPa] 0.7 Nominal filtration rating*3 [mm] 0.1 (Filtration efficiency: 95%

S. l AR2001 2501 3001 : Max.3.5t :-t-tt ., AR4001 : Max.5.0t ~ I II; a -tp ort cenler (fJ ~ ~c=Pr r-IN j~ OUT f= 0 .bj=J ~ A * N P Q Bracket mounting dimensions Model Port size A B C 0 E F G H J K L M AR2001 1/8 1/4 40 95 17 40 35 30 34 44 5.4 15.4 55 2.3 33.5 25 8 33 AR2501 1/4 3/8 53 102.5 25 48 32 30 34 44 5.4 15.4 55 2.3 33.5 25 843 42.5 32.5

L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tube O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateOption80.18

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateOption80.18

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard250.22

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard250.22

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard250.22

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard450.44

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard450.44

m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard450.44