The rotation angle can be adjusted between 0 to 100. The rotation angle can be adjusted between 0 to 100.
Series CQ2 Compact Cylinder: Long Stroke Type Double Acting, Single Rod 32, 40, 50, 63, 80, 100. How to Order . Precautions. Specifications. Construction. Dimensions . Series RQ Compact Cylinder with Air Cushion 20, 25, 32, 40, 50, 63, 80, 100. Features. Series Variations. Series RQ Compact Cylinder with Air Cushion Double Acting, Single Rod 20, 25, 32, 40, 50, 63, 80, 100 .
50.00 1000 1000 0 0 0 100 0 0 0.1 2 INC 50 10.00 1000 1000 0 0 0 100 0 0 0.1 () No.1(IN0ON) DRIVEON No.1 DRIVE No.
120 Pressure 0.6 MPa Pressure 0.6 MPa 80 100 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 80 60 0.5 MPa 0.4 MPa 60 0.4 MPa 40 0.3 MPa 0.3 MPa 40 20 20 0.2 MPa 0.2 MPa 0 0 20 40 60 80 100 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) 12-6-8 8 Series MHK2 Wedge Cam Operation Slide Guide Air Gripper Effective Gripping Force: Series MHKL2 Double
120 Pressure 0.6 MPa Pressure 0.6 MPa 80 100 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 80 60 0.5 MPa 0.4 MPa 60 0.4 MPa 40 0.3 MPa 0.3 MPa 40 20 20 0.2 MPa 0.2 MPa 0 0 20 40 60 80 100 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) 12-6-8 8 Series MHK2 Wedge Cam Operation Slide Guide Air Gripper Effective Gripping Force: Series MHKL2 Double
100 80 80 Holding force (N) Holding force (N) Pressure 0.6MPa L Pressure 0.6MPa 60 60 0.5MPa 0.5MPa 0.4MPa 40 40 0.4MPa 0.3MPa 0.3MPa 20 20 0 0 20 40 60 80 100 20 40 60 80 100 Holding point L(mm) Holding point L(mm) 2.4-10 Series MHK2 Wedge Cam Operation Slide Guide Air Gripper (2 Finger) Effective Holding Force: Series MHKL2 Single acting Indication of effective holding force The holding
120 Pressure 0.6MPa 80 100 Pressure 0.6MPa Holding force N Holding force N 0.5MPa 80 60 0.5MPa 0.4MPa 60 0.4MPa 40 0.3MPa 0.3MPa 40 20 20 0.2MPa 0.2MPa 0 0 20 40 60 80 100 20 40 60 80 100 Holding point L mm Holding point L mm 14 14 14 14 14 14 Series MHK2 Wedge Cam Operation Gripper Effective Holding Force: MHKL2 Series Double Acting The holding force shown in these tables represents the
Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .
60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160 VAC side pressure (kPa) Flow rate (l/min (ANR)) 14-5
ZSE20 ISE20 100 kPa 0 100 kPa 500 kPa 1 MPa Pressure range ZSE30 ISE30 ZSE30 ISE30 Switch ZSE40 ISE40 For vacuum pressure 101 kPa 0 ZSE30A 10 kPa 105 kPa ZSE10 ISE10 For compound pressure 100 kPa 100 kPa ISE70 ZSE30AF 105 kPa 105 kPa ZSE80 ISE80 For positive pressure 100 kPa 1 MPa ISE30A 105 kPa (0.105 MPa) 1.05 MPa PS Rated pressure range of switch Set pressure range of switch ISA3 ISA2
0.15 mm 0.3 mm 0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of
Models suitable to satisfy the requirement of 100 (N) are CY332 or CY340. 300 100 200 50 100 20 30 40 50 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10111213 7 8 9 1 01 11 21 3 1 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B25 500 300 200 100 20 30 40 50 10 Useable range 5 1 0 1 2 3 4 5 6 7 8 9 10111213 Distance
Applicable cylinder bore size (mm) Metric sizes (mm) Inch sizes (inches) Cylinder side port size Elbow type Model AS121F AS221F AS321F AS421F 3/16 1/4 5/16 3.2 4 6 8 10 12 6 to 20 20 to 40 40 to 63 63 to 100 1/8 5/32 3/8 1/2 M5 1/8, 1/4 1/4, 3/8 1/2 Universal type AS131F AS231F AS331F AS431F 6 to 20 20 to 40 40 to 63 63 to 100 M5 1/8, 1/4 1/4, 3/8 1/2 Speed controller with One-touch fitting
200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 200 300 400 500 600
Models suitable to satisfy the requirement of 100 (N) are CY332 or CY340. 300 100 200 50 100 20 30 40 50 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10111213 7 8 9 1 01 11 21 3 1 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B25 500 300 200 100 20 30 40 50 10 Useable range 5 1 0 1 2 3 4 5 6 7 8 9 10111213 Distance
Allowable kinetic energy (Graph (1)) Extension locking Retraction locking 100 100 63 Load weight kg Load weight kg 63 50 50 40 40 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 32 32 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 1 1 100 500 Maximum speed mm/s 100 500 Maximum
Gripping point L mm Gripping point L mm MRHQ25 MRHQ25 120 100 Pressure 0.2MPa 100 Note: 1in = 25.4mm 1MPa = 145psi 80 Pressure 0.2MPa 80 Overhang H mm Overhang H mm 60 0.3MPa 0.5MPa 0.6MPa 0.7MPa 60 0.7MPa 0.4MPa 0.3MPa 0.4MPa 40 0.5MPa 40 0.6MPa 20 20 0 20 40 60 80 100 0 20 40 60 80 100 120 Gripping point L mm Gripping point L mm 4 Rotary Gripper Series MRHQ Effective Gripping Force Effective
: 0.4 MPa Supply pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
L8 = 16n + 118.5 100 Drawing shows a SC case.
With auto switch: MDSUB3 1) 24: When using D-90/90A/S99(V)/T99(V)/S9P(V) 30: When using D-97/93A 2) 60: When using D-90/90A/97/93A 69: When using D-S99(V)/T99(V)/S9P(V) CRB2 CRBU2 If the adjustment bolt is removed, rotation will be approximately 270 for the single vane type and 100 for the double vane type.