CRB1BW635 0.030 0 5 0.030 25 0 83 60 PORT 4-R7.5 Top ports (port position): CRB1BW63-SE, CRB1BW63-DE 75 0 0.052 28h9 17 0.006 0.017 15g6 5 B port B port 25 45 80 21 When the B port of body (B) is threaded, it is closed with a Rc 1/8 plug. 3 14 3 14 29 22 Body (B) 15 Body (A) 2-Rc 1/8 A port 14 14.9h9 0 0.043 12 15g6 0.006 0.017 28h9 0 0.052 25 A port B port 75 2-Rc 1/8 8 (8) 82 27
CJ216 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.
270 0.3 (173) Rc1/ 4 (10) 100 100 Unclamp side port (30.2) (30.2) 306 139 360 Limit switch Note 1) Rc1/ 4 Clamp side port 0 4 x 8H7( ) through 0.015 82 0.05 143 115 50 4 x 14 through 320 330 0.05 (mm) A B C 200 Arm type S200 S240 340 29 240 360 19 Note 1) This product does not include the limit switch.
39 31 3 50 42 4 61 53 16 193 185 18 215 207 10 127 119 12 149 141 14 171 163 8 105 97 601
Rubber Seal 5 Port Solenoid Valve Series SX3000/5000 Low power consumption: 0.65W (with light) (Current value: 27mA, 24VDC) Compact with high flow rate Cv factor 1.7 to 3 times greater with same body width as previous series High reliability Long life exceeding 50 million cycles Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise Type
Coefficient factors Inlet air temperature (oC) 35 40 45 50 55 60 65 70 75 80 1.58 1.46 1.09 1.00 0.79 0.64 0.55 0.51 0.49 0.47 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 to 1.6 0.67 0.79 0.88 0.91 1.00 1.02 1.04 1.09 Ambient temperature (oC) 20 25 30 35 40 45 1.19 1.13 1.06 1.00 0.90 0.77 Calculation example: The air flow capacity when the dew point of IDFC60 is set to 10 oC
Thomas Oil-less WOB-L Piston Compressor / Vacuum Pump Flow Rate: 2.3 CFM / 65 LPM , 2.3 CFM / 65 LPM, Max Pressure: 75 PSIG / 5.2 bar , 75 PSIG / 5.2 bar, Max Vacuum: 27.2 in HgV / -921 mbar , 27.2 in HgV / -921 mbar, RPM (60 Hz): 1335, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase Series Configured Datasheet.
Dimensions . 46 47 48 50 52 52 53 54 54 55 55 56 57 58 60 60 60 61 62 63 65 65 65 66 66 67 67 68 69 69 70 70 71 72 73 75 75 75 77 77 78 78 78 79 80 82 84 84 84 85 86 87 87 88 89 90 Series AS * 2 * 0-D Speed Controller Adjustable by Flat Head Screwdriver: Standard Type Elbow Type \(Metal Body\) . Specifications. How to Order . Construction. Dimensions .
[IDFA125F-38/40] () (10 2m) (100.7m) 20 4x R2 1/2 R2 1/2 1130 78 9351 267 1120 655 75 64 (17 ) 40 1276 1375 R ) (14~18) () P.1-5 P.1-5 P.1-5 7122 20 350 700 752 IDFA100F150F 6 4 6.3 IDX-OM-U022 6.
The 50 Hz and the 60 Hz inverter pumps have the same capacity. (There is no pump capacity difference between the 50 Hz and the 60 Hz.)
Standard stroke 6 10 15 20 25 32 40 50 63 6mm 10mm 15mm Port thread type 20mm Bore size 6, 10, 15 Type M thread Rc NPT G Symbol 25mm 32mm Nil 20, 25, 32, 40 40mm TN TF 50, 63 50mm 63mm Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) 300 6 50, 100, 150, 200 500 10 15 20 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100
bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt Configuration Shock absorber model MY1 W MY1 W Without spacer 0 to 6 6 to 12 12 to 18 0 to 11.5 11.5 to 23 23 to 34.5 0 to 12 12 to 24 24 to 36 0 to 16 16 to 32 32 to 48 0 to 5.6 5.6 to 11.2 11.2 to 16.8 0 to 20 20 to 40 40 to 60 0 to 25 25 to 50 50 to 75 Stroke adjustment range
50 to 75 16 20 25 32 40 50 63 Head cover Spacer length (X416) Spacer length (X417) (Any fine strokes outside the parameters in the adjustment ranges above are considered to be a special order and processed accordingly.)
Note 1) C 5 to 35 Cooling capacity 50/60 Hz Note 3) kW 9.0/9.5 13.0/14.5 Heating capacity 50/60 Hz Note 4) kW 1.7/2.2 2.5/3.0 Temperature stability Note 5) C 1.0 Circulating fluid system Rated flow 50/60 Hz (Outlet) Note 6) L/min 42/56 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50/60 Hz Note 7) L/min 28/42 Tank capacity L 18 Circulating fluid
40 40 45 50 45 63 45 80 45 100 Mountable models 50 Note) The operating range above indicates average values at room temperature including hysteresis (assuming approximately 30% dispersion).
/60Hz 3 kW 9.0 / 9.5 13.0 / 14.5 Heating capacity4 kW 1.7 / 2.2 2.5 / 3.0 Temperature stability5 oC 1.0 Rated flow rate 50/60Hz (Outlet) 6 L/min 42 / 56 Pump capacity Maximum flow rate 50/60Hz L/min 55 / 68 Maximum lifting height m 50 Minimum operating flow rate 50/60Hz 7 L/min 28 / 42 Circulating fluid system Tank capacity L 18 Circulating fluid outlet, circulating fluid return port Rc3/
100 VAC, 50/60 Hz 200 VAC, 50/60 Hz Nil N T F Standard Rc Nil Z None With light/surge voltage suppressor NPT 1 110 VAC, 50/60 Hz Option NPTF S With surge voltage suppressor 220 VAC, 50/60 Hz G 2 position double 5 6 9 24 VDC 12 VDC Note) Indicator light is not available for grommet type.
/60 Hz 230 VAC 50/60 Hz 191 Thermo-chiller Basic Type HRSE Series Circulating Fluid Temperature Controller Simple function and performance Cooling capacity 1.2, 1.6, 2.2 kW (60 Hz) Power supply 100/200 VAC (50/60 Hz) 230 VAC (50/60 Hz) Triple control Compressor, fan and electronic control valve can be controlled depending on the heat load from the user s equipment.
Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability 0.1C Temp
Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.