SI Unit: DeviceNet, Input Block Stations: None, Input Block COM: +COM, Stations: 7 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 5/32" One-touch Fitting, Mounting Method: Direct Mounting, US Option: Preferred US Option for DeviceNet Type
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 7 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 7 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mount w/o DIN Rail
SI Unit: QW (DeviceNet), Input Block Stations: 53 [5 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D (DIN Rail Mounting), US Option: X160US (Preferred US Option for DeviceNet Type)
SI Unit: DeviceNet, Input Block Stations: 53 [5 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mounting, US Option: Preferred US Option for DeviceNet Type
SI Unit: QW (DeviceNet), Input Block Stations: 53 [5 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 20 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
SI Unit: DeviceNet, Input Block Stations: 53 [5 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 20 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 1/4" One-touch Fitting, Mounting Method: DIN Rail Mounting, US Option: -
R1 port A, B port D side U side P port Port R2 0 A Without SI unit With general type SI unit (Series EX300) Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System Electrical entry D side U side IP65 compatible B Cable length 0.6 m Cable length 1.5 m Cable length 3 m U0 U1 U2 D0 D1 D2 Note) Shown VV5Q41-05C12FD0 Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System (2 power
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 7 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 7 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 1/4" One-touch Fitting, Mounting Method: DIN Rail Mount w/o DIN Rail
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 7 Stations, P, E Port Entry: U (U Side 2~10 Stations), SUP/EXH Block Assembly: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 7 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Enclosure: IP67, SI Unit: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: -COM, Stations: 7 Stations, P, E Port Entry: U Side 2~10 Stations, SUP/EXH Block Assembly: Internal Pilot, Built-in Silencer, A, B Port: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, DIN Rail Option: -
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: D-sub connector compatible tie-rod base manifold, Number of Inputs/Outputs: -, Connector: Upward Connector, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port), Specification
Stations: 7 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 4 (Input Block 4 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)
Stations: 7 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 5 (Input Block 5 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)
Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 0 (w/o Input Block), Input Block: w/o Input Block, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: D (DIN Rail Mounting), Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)
Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 0 (w/o Input Block), Input Block: w/o Input Block, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)
Stations: 11 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 3 (Input Block 3 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)