Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Contact P/A regarding other voltages.
OUT 1 Thread type Rc NPT NPTF G Nil N T F IN Voltage 1 2 3 4 5 6 36 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC 230VAC Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Symbol 01 02 03 04 06 Class 4 Class B with AC has a built-in rectifying circuit. Class H is AC only. Without rectifying circuit. Contact P/A regarding other voltages.
Add a "" in front of the part numbers for solenoid valves, etc., to be mounted. 2 3 4 Class 2 Class 3 Class 4 Enter together in order, counting from station 1 on the D side. OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations D side U side 1 2 3 4 5 n Body material Brass Symbol D H Seal material FKM FKM 02 : 10 2 stations : 10 stations All IN ports are 3/8.
E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)
Note) A total of up to 3 SUP/EXH blocks can be mounted.
20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
15.2 40.4 35.4 15 18.5 11 R 1/4 17 34.4 29.4 55 18.5 46.5 28.2 19.7 10 ASD430F-02-10S 18.5 58 21 49.3 31 6 ASD530F-02-06S 12.8 74 17 48.3 25.2 20.3 8 ASD530F-02-08S 15.2 76 18.5 51.3 28.2 41.9 46.9 48.8 43.8 19.8 23 15.4 R 1/4 19 42.8 37.8 10 ASD530F-02-10S 18.5 80 21 54.1 32.6 23.1 12 ASD530F-02-12S 83 20.9 22 55.9 34.4 6 ASD530F-03-06S 74 17 12.8 48.3 25.2 20.3 8 ASD530F-03-08S 93 18.5
41.7 40.4 35.4 15.2 18.5 15 11 R(PT)1/4 17 34.4 29.4 18.5 55 28.2 46.5 19.7 10 ASD430F-02-10S 18.5 21 58 31 49.3 6 ASD530F-02-06S 12.8 17 74 25.2 48.3 20.3 8 ASD530F-02-08S 15.2 18.5 76 28.2 51.3 41.9 46.9 48.8 43.8 23 19.8 15.4 R(PT)1/4 19 42.8 37.8 10 ASD530F-02-10S 21 18.5 80 32.6 54.1 23.1 12 ASD530F-02-12S 22 20.9 83 34.4 55.9 6 ASD530F-03-06S 17 74 12.8 25.2 48.3 20.3 8 ASD530F-03-08S
pins) Connector entry direction Note Symbol Note Symbol Stations Stations 1: Perpendicular connector 2: Lateral connector 02 02 2 stations 2 stations Double wiring Double wiring LOCK FREE FREE 08 04 8 stations 4 stations LOCK 02 02 2 stations 2 stations Specified layout (Up to 16 solenoids possible) Specified layout (Up to 8 solenoids possible) 16 08 16 stations 8 stations Note 1) Double
Note 2) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it may result in a breakdown. Use a pipe tape for sealing. Recommended torque: 12 to 14 Nm.
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Operate the piston within a range such that collision damage will not occur at the end of the stroke. When a cylinder is used in a clamping mechanism, there is a danger of work pieces dropping if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage, etc.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 2. Speed adjustment is possible with meter-in/meter-out type speed controllers, but it may not be possible to obtain the cushion effect (smooth start-up, soft stop). 3.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
A B A B A Void A Void A B A B A B A A A B Double Double Double Double Double SY Sl unit Sl unit Single Single Single Single Single SYJ Stations Stations 1 2 3 4 5 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link System (Sharp) VK VZ ADDRESS NO. STATION NO.
2 A 2 A 24 VDC 0.63 A 1 A 1 A Temperature rise*5 25C 25C 25C 1 Leakage: The value at a differential pressure of 0.01 MPa or higher and an ambient temperature of 20C 2 This product has an IP67 enclosure, but if water enters the product, it may result in malfunction or breakage.