SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20C-T-02L-A3"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Rc1/8, Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .66138 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .55540 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, N, "VACUUM SWITCH

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 78 lb

Regulator Mounting: Direct Mount, IN/OUT Fitting Type: 06 [IN/ø4 (Straight) - OUT/ø4 (Straight)], Accessory: w/Pressure Gauge, Options: 0.35 MPa Setting and Non-Relieving, Unit Representation: -

Manifold Mounting: A (Direct Mount), Regulator Block Stations: 2 Stations, IN/OUT Piping Position: 06 [IN/ø4 (Straight) - OUT/ø4 (Straight)], Accessory: A (w/Pressure Gauge), Options: 3 (0.35 MPa Setting and Non-Relieving)

Regulator Mounting: A (Direct Mount), IN/OUT Fitting Type: 06 [IN/ø4 (Straight) - OUT/ø4 (Straight)], Accessory: A (w/Pressure Gauge), Options: 3 (0.35 MPa Setting and Non-Relieving)