Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1, Air Cylinder. 2.77 lb.

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less

Magnet: None, Mounting: E (Double End), Bore Size: 200 (2"), Stroke: 1800 (18"), Cushion: C (Urethane), Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC 3 PORT SOLENOID VALVE. Direct Op 3 Port Solenoid Valve, N.C.. 670.00000 lb. K44.

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector VALVE, SOFT START. SOFT START-UP VALVE. 1.25000 lb. 237.

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector VALVE, SOFT START. SOFT START-UP VALVE. 0.80000 lb. 239.

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

Mounting Position: In-line, Motor Type: T8 (400W Output, Absolute Encoder), Lead: B (LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 150mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: Housing B, Bottom, Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 5 (5m), Driver Type: B2 (LECSB2-T, 200

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN