Consult with SMC when using a cylinder in close proximity to a magnetic body (including proximity on any side) as shown in the figure below, as the operation of auto switches may become unstable.
If the lock plate comes off during operation, this may cause a serious accident, such as pad drop or workpiece drop.
Hysteresis may fluctuate due to the operating environments.
The flatness of the mounting face may deteriorate, the guides deviation range may increase and the sliding resistance may become greater. MX MTS MY CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mounting Caution CX 1.
If the tightening torque is insufficient, the fittings may become loose. Avoid any sealing tape getting inside the fluid passage. Ensure there is no leakage after piping. When mounting the fitting, a spanner should be used on the body (metal part) of the fitting only. Holding other parts of the product with a spanner may damage the product.
The accuracy may vary. Do not release the OUT side piping port of the product directly to the atmosphere without connecting piping. The accuracy may vary. [ oFF] Not used [F90] [ALL ] Setting of all functions Press the S button for 1 to 3 seconds. Press the S button for 3 to 5 seconds.
If it is mounted and joined by a person who does not have sufficient knowledge and skills, it may lead to failure such as leakage. When selecting adhesive for the vinyl chloride fitting (union), confirm that its heat resistance and endurance are compatible with the operating temperature of the fluids used. Otherwise, this may cause leakage and damage.
This may result in the valve falling to operate. If the supply pressure is pressurized for a long time with low quality air, then carbon powder or oil depleting materials contained in the compressed air might accumulate in the space between the spool and sleeve, which may cause the spool to stick.
If there is polarity, and polarity is mistaken, the device of the valve and power supply equipment may burn out and malfunction can occur. 2. When electric power is connected to the solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil burn out. 3. After completing the wiring, confirm that the connections are correct. 4.
Due to the different materials used, changing only the seal may prove inadequate.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
Inadequate differential pressure may increase the bleed amount from the bleed hole because of the wearing of internal part. This may effect on the performance. 3.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
There may be an error in the output voltage depending on this output impedance and the input impedance of customers' equipment.
It may also result in non-conformity to safety standards. Product handling Installation Do not drop, hit or apply excessive shock to the fieldbus system. Otherwise damage to the product can result, causing malfunction. Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws may be broken.
There may be an error in the output voltage depending on this output impedance and the input impedance of customers' equipment.
(Refer to page 17) If the tightening torque is exceeded the mounting screws may be broken. Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it. Wiring Avoid repeatedly bending or stretching the cables, or placing heavy load on them.
It may also result in non-conformity to safety standards. Product handling Installation Do not drop, hit or apply excessive shock to the fieldbus system. Otherwise damage to the product can result, causing malfunction. Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws may be broken.