Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: K (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KZ (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: K (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KZ (Plug Connector, 300mm)

Symbol: 20R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material/Port Size: w/o Sub-plate, Lead Wire Length, Electrical Entry, Light/Surge Suppressor: 10 (1000mm)

Body Type: T (Body Ported), Valve Option: Standard, Voltage: 6 (12 VDC), Electrical Entry: C (Conduit), Light & Surge Suppressor: None, Port Size: 02 (1/4, 8A), Thread: N (NPT)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m)

Body Size: 16, Motor Size: Standard, Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: CE1 (JXCE1, EtherCAT®), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: AP (LECPA, Pulse Input Type, PNP), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail)

Body Size: 16, Motor Size: L (Compact), Stroke: 6mm, Finger Option: C (Flat Type Fingers), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting)

Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 6 (12VDC), Lead Wire: C (Conduit)