Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [G] G, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity

Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [G] G, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: Operation Manual

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: None, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

SMC's new PFMB dual color digital flow switch allows for a wide range of flow measurement with one product.  The PFMB is suitable for use with air and nitrogen.  It's compact and space saving with an integrated flow adjustment valve.  The bypass structure limits the contact of moist air with the sensor, reducing degradation of the sensor and helps maintain accuracy.  2-color display improves

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: 1/4, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com