Function (Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 1/8, Flow Direction: [Right] From Left to Right, Control Side Connection Type: [One-Touch] One-Touch, Control Side, Connection Diameter: Ø1/4, Pressure Gauge: [With Pressure Gauge] With Pressure Gauge, Accessory: Pressure gauge, Set Pressure: 0.2 to 0.7 MPa, In Side Tube Size / Fitting Size: R1

Function (Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 1/8, Flow Direction: [Right] From Left to Right, Control Side Connection Type: [One-Touch] One-Touch, Control Side, Connection Diameter: Ø1/4, Pressure Gauge: [With Pressure Gauge] With Pressure Gauge, Accessory: Pressure gauge, Set Pressure: 0.05 to 0.2 MPa, In Side Tube Size / Fitting Size: R1

Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 1/8, Flow Direction: [Right] From Left to Right, Control Side Connection Type: [One-Touch] One-Touch, Control Side, Connection Diameter: Ø1/4, Pressure Gauge: [With Pressure Gauge] With Pressure Gauge, Accessory: Pressure gauge, Set Pressure: 0.05 to 0.2 MPa (with seal), In Side Tube Size / Fitting Size: R1

Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 1/8, Flow Direction: [Right] From Left to Right, Control Side Connection Type: [One-Touch] One-Touch, Control Side, Connection Diameter: Ø1/4, Pressure Gauge: [With Pressure Gauge] With Pressure Gauge, Accessory: Pressure gauge, Set Pressure: 0.2 to 0.7 MPa (with seal), In Side Tube Size / Fitting Size: R1

Pressure range: 15 to 145 PSI (0.1 to 1 MPa) ; Ambient and fluid temp range: 23 to 140°F (-5 to 60°C) ; Option for meter-out or meter-in type control ; One-touch fitting provides easy tube mounting/removal ; Applicable tube size: ø4, ø6, ø8, ø10, and ø12 ; Thread port size: M5, R1/8 to 1/2 ; The port thread has sealant (except M5 type), to save installation time and reduce the possibility

Pressure range: 15 to 145 PSI (0.1 to 1 MPa) , Ambient and fluid temp range: 23 to 140and#176;F (-5 to 60and#176;C) , Option for meter-out or meter-in type control, One-touch fitting provides easy tube mounting/removal, Applicable tube size: °4, °6, °8, °10, and °12, Thread port size: M5, R1/8 to 1/2 , The port thread has sealant (except M5 type), to save installation time and reduce the

Pressure range: 15 to 145 PSI (0.1 to 1 MPa) , Ambient and fluid temp range: 23 to 140and#176;F (-5 to 60and#176;C) , Option for meter-out or meter-in type control, One-touch fitting provides easy tube mounting/removal, Applicable tube size: °4, °6, °8, °10, and °12, Thread port size: M5, R1/8 to 1/2 , The port thread has sealant (except M5 type), to save installation time and reduce the

Series: LEKFS, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 200, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R1 (1.5), Controller: CP1 (JXCP1, PROFINET, Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)

Motor Mounting Position: D (In-line Motor Type), Lead: K (8mm), Stroke: 50mm, Motor Option: w/o Option, Body Option: S (Dust-protected), Mounting: w/o Side Holder, Actuator Cable Type, Length: R1 (1.5m), Controller: C61 [Parallel Input (PNP)], Mounting: 7 (Screw Mounting), I/O Cable: 1 (I/O Cable, 1.5m)

Motor Mounting Position: R (Basic Type), Lead: K (8mm), Stroke: 50mm, Motor Option: w/o Option, Body Option: S (Dust-protected), Mounting: w/o Side Holder, Actuator Cable Type, Length: R1 (1.5m), Controller: C61 [Parallel Input (PNP)], Mounting: 7 (Screw Mounting), I/O Cable: 1 (I/O Cable, 1.5m)

.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)

.: 02 (R1/4, Rc1/4), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)

Size: 40, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: D (Double Clevis, Top Mounting), Actuator Cable Type, Length: R1 (1.5m), Controller: C61 [Parallel Input (PNP)], Mounting: 7 (Screw Mounting), I/O Cable:

Sensor Range: 7 [For Positive Pressure (0~10MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: B (PNP open collector 2 outputs, Lead Wire: N (None), OUT1 Output Type: P (Normal Output), OUT1 Set Value: 005 (0.5 MPa, 50 kPa, 250 kPa, 1.0 MPa, 2.5 MPa, 5 MPa), OUT1 Hysteresis (H1): 1 (0.01 MPa, 1 kPa, 5 kPa, 0.02 MPa, 0.05 MPa, 0.1 MPa), OUT2 Output Type: N (Reversed Output

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A), Operation Manual: K (Operation