A B C D E F G H LAT3-10 10 49 4 60 50 4 10.5 LAT3-20 20 69 6 25 90 80 14 20.5 LAT3-30 30 89 6 25 120 110 24 30.5 13 - LAT3-50 Note 1) Refer to Mounting screw specifications and tightening torques in section 4.3 Mounting (P.24). Note 2) The length of the part of the dowel pin inserted into the positioning hole should be shorter than the specified depth.
OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 6.2.1 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-R016 Contents 6.3 Option T [High-pressure pump mounted] . 6-2 6.3.1 Option T [High-pressure pump mounted] . 6-2 6.4 Optional Accessories [Electric
No.VT315-OMH0002-D PRODUCT NAME Direct Operated 3 Port Solenoid Valve MODEL / Series / Product Number Series: VT315 Contents Safety Instructions -2,3 Precautions on Design / Selection -4,5 Mounting -5 Piping -5 Wiring -6 Lubrication -6 Air Supply -6 Operating Environment -6,7 Maintenance -7 Specific Product Precautions -810 Trouble shooting -11,12 -1VT315-OMH0002-D Safety Instructions These
Release the alarm referring Chapter 6.
o Linseed Oil o o D a tr o o Lubricating Oil tr o tr tr o o o Machine Oil tr B D D D tr D D Methyl Alcohol D o o o o I I Methyl Ellryl Ketone o o o I o o Mineral Oil o D o tr tr tr o Motor Oil o o tr n o Naphtha o o o Nitrate 10oi0 I I I I I V V Ozone o o o o I V V Ozon Low Concenlration o tr o o Petroleum o o o o o tr Petroleum Oils a o tr o o D Soapy Water EI B o o o o B tr Sodium Chloride
-6 = 9.0 x 10-6 (kgm2) Moment of inertia around Z axis IA = IZ1 + m1r12 X 10-6 z r2 z2 B part r2 = 47(mm) Calculation of weight m2 = d x e x f x Specific gravity m2 = 5 x 10 x 12 x 2.7 x 10-6 = 0.002 (kg) Moment of inertia around Z2 axis IZ2 = {m2 (d2 + e2)/12} x 10-6 IZ2 = {0.002 x (52 + 102)/12} x 10-6 = 0.02 x 10-6 (kgm2) IB = 0.02 x 10-6 + 0.002 x 472 x 10-6 = 4.4 x 10-6 (kgm2) I =
d A IZN10E-01 02m06 6 3.5 IZN10E-01 02m07 1/4" 7 34.7 26 2 x M3 x 0.5 thread depth 10 11 291 *1 Dimension of the resin part in described in the Mounting Warning note 3 (page 24). 18.31 One-touch fitting (Elbow) IZN10E-mm 16 17 D B C Applicable tubing O.D. d 180 [mm] Model d B C D IZN10E-mm16 6 22 16 11.5 IZN10E-mm17 1/4" 24.5 18.5 12 Female threads for piping (Rc1/8) IZN10E-11mm 14 Rc1/
OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-R005 Contents 6.2.1 Option M [DI water (Pure water) piping] . 6-2 6.3 Optional Accessories [Electric resistivity /conductivity sensor set] . 6-2 6.3.1 Optional Accessories [Electric resistivity/conductivity
Note 6) Parts other than the wetted parts are made of carbon steel and painted (silver).
Removing Loosen clamp ring (1), and separate the multiconnector into two parts, multiconnector into two parts, socket side and plug side. (1) Clamping ring K (3) Case B M D H Insertion and removal of tube D + Driver (5) Barb (6) Clamp bolt (3) Case (2) Stopper Connection 1.
ECC-PNAL-20MR-A (AC100-240V) ECC-PNAL-20MR-D (DC24V) ECC-PNAL-20MT -D (DC24V TRANSISTOR OUTPUTS) 20 1/0 (12 inputs/8 outputs) stand alone controller ECC-PNAL-10MR-A (AC100-240V) ECC-PNAL-10MR-D (DC24V) ECC-PNAL-10MT -D (DC24V TRANSISTOR OUTPUTS) 10 1/0 (6 inputs/4 outputs) stand alone controller ECC-PNAL-6MR-A(AC100-240V) 6 1/0 (4 inputs/2 outputs) stand alone controller How T o Order Specifications
Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
Caution When tightening the auto switch mounting screw, use a watchmakers screw driver with a handle about 5 to 6 mm in diameter. When tightening the mounting bracket screw, use a 1.5mm hexagon wrench. The tightening torque should be approximately 0.1 to 0.2Nm for types D-A9 and D-F9, and 0.05 to 0.1Nm for types D-Z7, D-Z8, D-Y5, DY6 and D-Y7.
Printed in Japan. 1st printing August, 1998 D-SMC.L.A. P-69.5 (JT)
S: B Throo h hole standard A Both ends ta d L Foot mount F Rod side Iia e Head side flan e Type of Auto Switch , No auto SWitch built in (high magnetic Bore Size D Clevis mount . ~ field resIstance ma net 50 50mm P7G 0P10 63 63mrn l'l14C D-P74 80 80mm i P7 D-P75 Cylinder Stroke D-PS P8!
Unit: N m Applicable models VHS20-D VHS30-D VHS40-D VHS40-06-D VHS50-D Max. moment (M) 14.5 16 19.5 35 45 Max. moment (M) = Length (L) x Load (F) Length (L) Load (F) 6. For piping into the exhaust port, recommended installing a silencer.
MY CY Proper Auto Switch Mounting Position MG A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 24.5 93.5 -X CYP32 33 122 20Data Mounting of Auto Switch When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.
MHL2-40D MHL2-40D1 MHL2-40D2 SMHL2C, #4 SMHL2C, #5 SMHL2C, #6 (#6+#7) 2.2-12
Pressure 0.7 MPa PM: Raised up to 0.43 MPa 6 x 6 pcs. 6 x 10 pcs. 6 x 8 pcs. 6 x 10 pcs. 6 x 8 pcs. 6 x 10 pcs. 6 x 10 pcs. Flow rate Q (Nl) Flow rate Q (Nl) Tube 2,000 Tube 2,000 mm 500 mm 6 x 8 pcs. 6 x 8 pcs. 500 mm 500 mm mm 6 x 6 pcs. 6 x 6 pcs. 6 x 6 pcs. 6 x 6 pcs.