When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

0.01 to 0.03C)Refer to performance chart.Approx. 1.3 gal (5 L)IN/OUT: Rc3/4Drain: Rc1/4 (with plug)Stainless steel 303, Stainless steel 304, EPDM, Ceramics, PP, PE, Polyurethane, SiC, PPS50 to 95F (10 to 35C) (no condensation)Within 145 psi (1 MPa)2.6 to 4.0 gpm (10 to 15 L/min)IN/OUT: Rc1/2Stainless steel 303, Stainless steel 304Single-phase 200 to 220 VAC ?

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EC, VX3 BODY PT 1/4NPT, 1.10231 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, HC, VX3 BODY PT 3/8, 1.77825 lb, Port sizeOrifice diameter (mm?)

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, VALVE, SOL, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2D, VFS5000, 3.74785 lb

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, BA, VQZ100 BODY

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, VALVE, BASE MOUNT (DC), VALVE, VQZ1000 VALVE, SOL 4/5-PORT, 2D, VQZ1000 NO SIZE RATING

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC