SMC Corporation of America
Elite Part Number Search
Search Results "NCQ2B40-45+5D-XC11"

The SX series valves are available with numerous manifold options which allow for easier installation and improved operation., GASKET TYPE 45, VALVE, SS5Y3 MANIFOLD SY3000, 21, SS5Y3 NO SIZE RATING, .00002 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROLLER, FLOW CONTROL, 45 lb

Remote monitor unit, Main screen has 2-color display showing flow, status of setting mode and error code, Output display w/indicator light, Display can be rotated in 45° increments, Easy operation and improved visibility, Digital Flow Monitor for Water, DIGITAL FLOW SWITCH, WATER, PF3W, 100 lb

Series CJ2 is auto switch capable Non-rotating, direct mount, Single acting, spring return/extend, Bore size *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 357, 0.042 lb

panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, air cooled, CHILLER, 729, 45

panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, air cooled, CHILLER, 729, 45

panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, air cooled, CHILLER, 729, 45

panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, air cooled, CHILLER, 729, 45

The settings of the master pressur, 2-Color Hi Precision Dig Pres Switch, PRESSURE SWITCH, ISE40, ISE40A, 841, 45 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 957, 47.7 lb

Series CJ2 is auto switch capable Double acting, single rod, end lock cylinder, 16mm bore, Mounting types: basic, axial foot, front flange, double clevis, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, 175, 200, Auto switch capable, CYL, END LOCK, SW CAP, ROUND BODY CYLINDER, 353, 0.028 lb

Air pilot type process pump, Discharge rate 5 to 45 /min, Compact, large capacity, Easy maintenance due to structural design that allows the diaphragm and check valve to be replaced individually, 2 to 5 time longer life than that of conventional pumps, Process Pump, PROCESS PUMPS, PA, PAX, PB, 6.5 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, CONNECTORS, KQ2 FITTING, JX, KQ2 10MM, .06081 lb

Air pilot type process pump, Discharge rate 5 to 45 /min, Compact, large capacity, Easy maintenance due to structural design that allows the diaphragm and check valve to be replaced individually, 2 to 5 time longer life than that of conventional pumps, Process Pump, PROCESS PUMPS, PA, PAX, PB, 6.5 lb

N.C. valve type, class B coil insulation, Power consumption 2.5w, IP65 enclosure, Seal: NBR (low concentration ozone resistant type: FKM), Resin body 2 port valve, 2 PORT VALVE, 45 lb

Series CJ2 is auto switch capable Non-rotating, direct mount, Single acting, spring return/extend, Bore size *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 357, 0.079 lb

Adjustment range: 0.5 to 3mm.Pin clamp cylinder with positioning and clamping at one time, 55 types of guide pins, 4 body types for a broad range of installation conditions, Optional locking mechanism, Precision adjustment of clamping height is possible by choosing the with shim type, Adjustment range: 0.5 to 3mm, GUIDE PIN, PIN CLAMP CYLINDER, 381, 45 lb