If they enter the inside of products, they could cause products to malfunction, lower performance or damage the element. d.
(no condensation) Temperature characteristics 5%F.S. max. (0 to 90 C, 25 C reference) Withstand voltage 1000 VAC, for 1 minute between the external terminals and case Insulation resistance 50 M or more (at 500 VDC) between external terminals and case Standards and regulations CE, RoHS Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Materials of parts in contact with fluid SUS, NBR 4,
Converter nominal size Electrical entry of solenoid valve Through the availability of a wide range of series in terms of converter capacity and valve unit flow rate control capa63 100 160 63mm 100mm 160mm G C D Air operated Grommet Conduit DIN terminal bility, speeds as high as 200mm/s (throttle valve) can be achieved with a 80 cylinder.
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Not required (Non-lube) 50 to 1000 mm/s 50 to 700 mm/s Operating piston speed Up to 250 st: , 251 to 1000 st: , 1001 to 1500 st: , 1501 to 2000 st: +1.0 0 +1.4 0 +1.8 0 +2.2 0 Allowable stroke tolerance Both ends (Air cushion) Cushion JIS Symbol Double acting Port size G 1/8 G 1/4 G 1/4 G 3/8 G 3/8 G 1/2 G 1/2 Basic, Axial foot, Rod end flange, Head end flange, Single clevis, Double clevis
(mm) 2.5 4 6 7.5 9 12 2.18 3.48 4.57 6.99 9.56 D Black (B) White (W) MS Red (R) T Blue (BU) Burst pressure (MPa) Yellow (Y) TS0425, TS0604 VMG Green (G) Other than T00425, T0604 Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Max. operating pressure (TS0425, TS0604) Max. operating pressure (For other than TS0425, TS0604) Air Fluid Max. operating pressure (at 20C) Operating
(mm) 4 6 8 10 12 M I.D. (mm) 2.5 4 5 6.5 8 H White (W) D Black (B) Red (R) MS Blue (BU) T Yellow (Y) Green (G) VMG Air/Nitrogen gas/Water (Pure water) (1) Fluid Max. operating pressure (at 20C) 0.7 MPa (2) Min. bending radius (mm) 10 20 25 30 40 Burst pressure Refer to the burst pressure characteristics curve.
Cooling capacity None Nil C D N Z Analog communication Symbol 001 002 004 008 Cooling capacity DeviceNet communication 1 kW NPT fittings 2 kW Temperature range setting Circulating fluid automatic recovery 4 kW Temperature range setting 1 kW 2 kW 4 kW 8 kW Symbol L H W 8 kW 20 to 40C 20 to 90C 20 to 90C Specifications (For details, please consult our Product Specifications information.)
Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Non-lube Double acting, 25, 50, 75, 100, 125, 150, 200 Up to 1500 Single rod (40 to 63) 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note 1) When exceeding the standard strokes above, the particle generation class may not be satisfied.
Thermo-chiller Series HRW Fluorinated Fluid Type SEMI How to Order 002 H HRW Fluorinated FluidType Option Cooling capacity Option Symbol Symbol 002 008 015 030 Cooling capacity None Nil C D N Z 2 kW Analog communication 8 kW DeviceNet communication 15 kW NPT fitting 30 kW Circulating fluid automatic recovery Pump inverter control Temperature range setting Pump inverter control None Applicable
U side Base mounted plug-in 3 1 2 Stations D side 9
Series VS R8 S HOW TO ORDER ISO5599/2 VALVE MANIFOLD VV8 2 5 03 TU1 03 D T W1 W1=NEMA 4 ISO Size 1 Size 1 Port Thread Code 2 Size 2 3 Size 3 NIL Rc (PT) T NPTF F G(PF) Location of port 1(P), 5(EA), 3(EB) Number of Stations D D side 2 2 stations U U side B Both side 9 9 stations Size of port 1(P), 5(EA), 3(EB) Symbol Size Applicable ISO size 02 1/4 Size 1 U side option 03 3/8 Size 1
Port size Instruction manual Symbol Description Flow rate range 10 With instruction manual (Leaflet: Japanese and English) None Nil N 25 50 11 01 02 N01 N02 F01 F02 C4 C6 C8 N7 Rc1/8 Rc1/4 NPT1/8 NPT1/4 G1/8 G1/4 Unit specification With unit switching function M Nil Fixed SI unit Note) Note) Fixed unit: Real-time flow rate: l/min Accumulated flow: l 4 (5/32") one-touch fitting 6 one-touch
E ) (0.1N m) 8 No.VP300-OMP0001 VP Series VP Series VP Series VP Series/ / / / DIN DIN DIN DIN DIN(EN175301 DIN(EN175301 DIN(EN175301 DIN(EN175301-803) 803) 803) 803) Y DIN EN175301-803B 10mm DIN D DIN ( ( ( ( ) ) ) ) DIN IP65() DC (S,Z )+(4.5~7) IP65() 180 4.5~7 () JIS C 3306 0.5~1.5mm 2 3 O JIS C2805 R1.254M Y 1.253L 1.5 Y D 2.5~3.75Nm 0.5~0.6Nm () 3 0.4~0.5Nm () () () 9 No.VP300
69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate the case of piping port position "Nil".
-11 Pam3/sec Operating temperature Gate Part5120(During bake-out150) Actuator part590 Except Auto switch Fluid Inert gas Operating Time 1 sec or less * Auto switch D-A93 Operating temperature2060 Seal material FKM Bellows AM350 Gate A6063 Body A5052 Bonnet A6061 Gate bolt SUS316 Others SUS304 Main material of vacuum part Mechanical parts Piping size Rc1/8 Exhaust direction Free End-Lock (
Status Condition 0 No supply voltage SP Status of solenoid power supply 1 Supply voltage OK 0 Short circuit DI Status of sensor power supply 1 Normal Output area mapping Output data MSB LSB MSB LSB Offset (word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -28No.EX-OMK0004-B Output No. assignment Combinations of output data and valve
Electric circuit diagram 8 6. Installation 9 7. Electrical wiring 10 8. Maintenance 11 9. Mounting accessories (option) 12 10.