(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided

Besides, do not connect a PLC, which can detect 1 [mA], since there is a leak current of 1 [mA] in OFF state. 0 Time Hi 5 to 40 [mA] B 10 [ms] or shorter B 10[ms] or shorter Brown OUT(+) Main circuit of switch Main circuit of switch Load A 5 [ms] or longer 12 to 24 [VDC] When the auto shift input is 10 [ms] or shorter, switch output responds.

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F5NTL (With indicator light) CRB2 D-F5NTL Auto switch model Wiring type 3-wire CRBU2 Output type NPN Output operation Off-delay CRB1 Operating time 1 ms or less Off-delay time 200 50 ms MSU Applicable load IC circuit, Relay, PLC CRJ Power supply voltage 5, 12, 24

Maximum load current 80 mA Maximum applied voltage (NPN output) 30 VDC Switch output Internal voltage drop (Residual voltage) NPN: 1 V or less (Load current 80 mA) PNP: 1.5 V or less (Load current 80 mA) Delay time 1 1.5 ms or less (delay time available for anti-chattering function: 20, 100, 500, 1000, 2000, 5000 ms) Hysteresis mode Variable from 0 2 Window comparator mode Hysteresis Protection

(reference 25 oC) Switch output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. load voltage 30 VDC (at NPN output) Residual voltage 1 V or less (at load current 80 mA) Output protection Short-circuit protection Output mode Hysteresis mode, window comparator mode Response time 2 ms (10 ms, 50 ms, 0.5 s, 1 s can be selected) Hysteresis Variable Voltage output 1 to

The MS green LED is flashing The MS red LED is flashing Set up configuration correctly. 5.2. PLC setting (Configuration) The MS red LED is on Stop using the product. Contact your sales representative. Does not operate at all.

Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 8.4 Controller input signal response Move occasionally Signal timing Check the timing of the signal from the PLC to

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring

Incorrect wiring MS: Green LED flashes (1) Setting error (2) PLC has stopped operating, (1) Set up configuration configuration correctly. or the communication is idling. (2) Set PLC in RUN status. MS: Red LED flashes Set up the configuration correctly. 5.2 PLC setting (Configuration) Recoverable error (P.39) MS: Red LED is on Unrecoverable error Stop using the product.

Wireless System RoHS Usable even in welding environments High-speed connection Noise resistance Communication response Signal response time: 5 ms Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 5 ms From power supply ON to start of communication: Min. 250 ms*1 *1 For wireless slave Communication cables not required Compatible protocol Number of I/O points Reduced wiring work,

Incorrect wiring MS: Green LED flashes (1) Setting error (2) PLC has stopped operating, (1) Set up configuration configuration correctly. or the communication is idling. (2) Set PLC in RUN status. MS: Red LED flashes Set up the configuration correctly. Refer to Hardware Configuration (P.20) for details. Recoverable error MS: Red LED is on Unrecoverable error Stop using the product.

Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and driver scanning delays can occur. 8.4 Response time for the driver input Check the timing of the signal from the PLC to the driver.

Check the state GW unit MS LED Refer to fault of the GW unit. is OFF. No.1. GW unit MS LED Refer to fault is ON red. No.2. GW unit MS LED Refer to fault is flashing red. No. 3. GW unit MS LED is flashing green. Refer to fault No. 4. GW unit NS LED Refer to fault is OFF. No. 5. GW unit NS LED is Refer to fault ON red No. 6. GW unit NS LED is Refer to fault flashing red. No. 7.

Momentary change Pressure Set value P_1 H_1 t (ms) t (ms) Time Switch output operation under normal conditions ON OFF Time Switch output operation when anti-chattering function is on ON OFF Time Pressure range/Unit selection function (F0) Pressure range and displayed units can be switched with this function.

ZSE20A : 5.1 kPa ZSE20AF : 5.0 kPa Delay time Delay time of the switch output can be selected. 1.5 ms or less Display color Selects the output according to the display color. OUT1 ON : Green OUT1 OFF: Red -28No.PS-OMU0003-D [F 2] Setting of OUT2 Page 34 Same setting as [F 1] OUT1.