OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 16-3-11 11 Series PSE530/200 Operation 1: Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5 ms 20 ms 160 ms 640 ms SET Press SET button.
(mm) 8 2.5 4 5 6.5 H Black (B) TUS related accessories Inner sleeve Series TJ White (W) D Red (R) Blue (BU) MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Yellow (Y) Reinforces soft polyuretharane tubing.
Speed Vc Acceleration Aa Speed [mm/s] Total travel distance S Time [s] Positioning time Tp LAT3LAT3MLAT3FShortest positioning time [ms] 600 350 700 Shortest positioning time [ms] Shortest positioning time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g
Metric 1/8" to 1" 1/8" to 1/2" 1/8" to 3/4" 1/8" to 1 1/4" Inch Translucent, Red, Blue, Black Translucent, Red, Blue, Black Translucent Translucent Color KQ2, KQG2, KP, KP KQ2, KQG2, KP, KP One-touch fittings Applicable fitting series M, MS (Hose nipple type) M, MS (Hose nipple type) M, MS (Hose nipple type) Miniature fittings KF, KFG2 KF, KFG2 KF, KFG2 Insert fittings LQ series LQ series
It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.
Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms
(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided
Besides, do not connect a PLC, which can detect 1 [mA], since there is a leak current of 1 [mA] in OFF state. 0 Time Hi 5 to 40 [mA] B 10 [ms] or shorter B 10[ms] or shorter Brown OUT(+) Main circuit of switch Main circuit of switch Load A 5 [ms] or longer 12 to 24 [VDC] When the auto shift input is 10 [ms] or shorter, switch output responds.
Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F5NTL (With indicator light) CRB2 D-F5NTL Auto switch model Wiring type 3-wire CRBU2 Output type NPN Output operation Off-delay CRB1 Operating time 1 ms or less Off-delay time 200 50 ms MSU Applicable load IC circuit, Relay, PLC CRJ Power supply voltage 5, 12, 24
Maximum load current 80 mA Maximum applied voltage (NPN output) 30 VDC Switch output Internal voltage drop (Residual voltage) NPN: 1 V or less (Load current 80 mA) PNP: 1.5 V or less (Load current 80 mA) Delay time 1 1.5 ms or less (delay time available for anti-chattering function: 20, 100, 500, 1000, 2000, 5000 ms) Hysteresis mode Variable from 0 2 Window comparator mode Hysteresis Protection
(reference 25 oC) Switch output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. load voltage 30 VDC (at NPN output) Residual voltage 1 V or less (at load current 80 mA) Output protection Short-circuit protection Output mode Hysteresis mode, window comparator mode Response time 2 ms (10 ms, 50 ms, 0.5 s, 1 s can be selected) Hysteresis Variable Voltage output 1 to
The MS green LED is flashing The MS red LED is flashing Set up configuration correctly. 5.2. PLC setting (Configuration) The MS red LED is on Stop using the product. Contact your sales representative. Does not operate at all.
Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 8.4 Controller input signal response Move occasionally Signal timing Check the timing of the signal from the PLC to
30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS090 Series 5-14 HRX-OM-T004 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-R028 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
(at 25 oC) Model PSE57-02 PSE57-02-28 Fluid Applicable Gas or liquid that will not attack or corrode the materials of parts in contact with fluid Power supply voltage 12 to 24 VDC10% with 10% voltage ripple or less Electrical spec.
(Only for EX510-S 02 ) : Only mounting direction of the SI unit to the mounting bracket is different between EX510-S A and EX510-S B. Mounting direction can be changed from horizontal to vertical by changing the screws which construct the mounting bracket.
(Only for EX510-S 02 ) : Only mounting direction of the SI unit to the mounting bracket is different between EX510-S A and EX510-S B. Mounting direction can be changed from horizontal to vertical by changing the screws which construct the mounting bracket.
(Only for EX510-S 02 ) : Only mounting direction of the SI unit to the mounting bracket is different between EX510-S A and EX510-S B. Mounting direction can be changed from horizontal to vertical by changing the screws which construct the mounting bracket.
AR-OMT0015 PRODUCT NAME REGULATOR MODEL/ Series AR20K-(F,N)01 (F,N)02(B,E,G,H,M)(-1,N,R,Y,Z)-B AR25K-(F,N)02 (F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B AR30K-(F,N)02 (F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B AR40K-(F,N)02 (F,N)04(B,E,G,H,M)(-1,N,R,Y,Z)-B AR40K-(F,N)06(B,E,G,H,M)(-1,N,R,Y,Z)-B AR50K-(F,N)06 (F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B AR60K-(F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B Contents PAGE 1.