If the tightening torque is insufficient, the fittings may become loose. When connecting piping to the product, a spanner should be used on the metal piping attachment only. Using a spanner on other parts may damage the product. Avoid any sealing tape from entering inside the piping. Ensure that there is no leakage from loose piping.
If the tightening torque is insufficient, the fittings may become loose. When connecting piping to the product, a spanner should be used on the metal piping attachment only. Using a spanner on other parts may damage the product. Avoid any sealing tape from entering inside the piping. Ensure that there is no leakage from loose piping.
Bubbles may be generated depending on the piping design. Refer to an example of recommended piping system. Piping port (Tube) Connected to the fluid inlet at IN side and to the fluid outlet at OUT side. These safety instructions are intended to prevent hazardous situations and/or equipment damage.
The output condition also recovers to that before the power cut or de-energizing, but may change depending on the operating environment.
Otherwise, malfunction may result due to noise. Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
Otherwise, malfunction may result due to noise. Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
The warranty period of the product is 1 year in service or 1.5 years after the product is delivered,whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.
If excessive tightening torque over the specified range is applied, a mounting screw, mounting bracket, and product may be broken. Air and liquid leakage Check if air liquid are leaking from the piping. Noisy.
The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.
Otherwise, displacement of zero point of needle and deformation of Bourdon tube may be caused. Select the gauge in accordance with max. operating pressure. (2) Do not use the fluid which may corrode the material of contact part to liquid and gas.
When the humidity is low or the compressor is run for a short time period, drain may not be produced. Monthly check (1) The wire gauzes in the cooler section and for the motor fan and rear panel must be cleaned by means of an air gun or other device to prevent clogging.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
If tightened excessively, thread portion may be damaged and gasket may be deformed. This will cause air leakage. On the contrary, if tightened insufficiently, thread may loosen causing air leakage. 1. Cut the tube perpendicularly to the tube axis to a little longer length than required (use tube cutter TK-1, TK-2 or TK-3). 2. Pass the tube through the cap nut. 3.
However, backlash (about 0.1) may occur as the rotation speed increases. If this causes any problems during operation, readjust the center position. Plug cap 299
If the body is held while tightening bolts, etc., the guide section will be subjected to a large moment, and there may be a loss of precision.
Do not use a tool to mount the connector, as this may cause damage.
{Tightening torque: 0.8 to 1.2 Nm} If the exhaust of the double check block is throttled too much, the cylinder may not operate properly and may not stop intermediately. Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
Adjustment outside the prescribed ranges may cause malfunction of the product or failure of switches to operate. 2. Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3. The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure above. 376