VQ 0 5 1 1 0 1 10 CE compliant Series 10-VV5Q11-08C6SV 10-VQ1100-51 10-VQ1200-51 10-VQ1300-51 VVQ1000-10A-1 1 setManifold base part no. 2 setsValve part no. (Stations 1 to 2) 4 setsValve part no. (Stations 3 to 6) 1 setValve part no. (Station 7) 1 setBlanking plate part no.

VQ 0 5 1 1 0 1 10 CE compliant Series 10-VV5Q11-08C6SV 10-VQ1100-51 10-VQ1200-51 10-VQ1300-51 VVQ1000-10A-1 1 setManifold base part no. 2 setsValve part no. (Stations 1 to 2) 4 setsValve part no. (Stations 3 to 6) 1 setValve part no. (Station 7) 1 setBlanking plate part no.

to 63 20 20 CLQ 63 MLGP 50 RLQ 50, 63 50, 63 Load weight m (kg) 50, 63 MLU 10 10 50, 63 40 40 40 40 ML1C 50, 63 40 D40 -X 32 32 32 32 32 32 204 10 50 51 100 101 200 200 300 300 4 10 50 51 100 101 Data Stroke (mm) Stroke (mm) MLGPL80/100 MLGPL80/100 40 40 100 100 100 80 Load weight m (kg) Load weight m (kg) 100 80 80 80 100 100 80 10 10 80 6 10 100 200 200 300 300 25 26 50 51 6 10 100 25

50 50 Load weight m (kg) Load weight m (kg) 40 40 50 50 40 40 32 32 10 10 25 25 32 32 20 20 25 25 20 20 1 1 10 50 100 200 10 50 100 200 Eccentric distance l1 (mm) Eccentric distance l1 (mm) (16) Over 50 Stroke V = 400 mm/s (15) 50 Stroke or Less V = 400 mm/s 100 100 100 100 50 50 80 80 63 63 Load weight m (kg) Load weight m (kg) 50 50 10 10 40 40 32 32 25 25 1 20 20 1 10 50 100 200 0.7 10

1 o q u r y e @6 @5 @3 @7 CY1L10 to 40 @2#9 @0$0 t !9 #5$2 #8 !2 !0 !6!7@4 @1 !8 !4 !5 $0 @8 #7 #6 $1 F G Area G (10) Enlarged view F 10, 15 w u i o !1 #2 q !3 r y e @6 @5 @3 $1 #0 @7 #1 10 Component Parts Note No. Description Material No.

9 y !7 q e @0 !0 o @2 @3 !5 u t !8 @1 r @4 w MX MTS MY 12 to 40 CY @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !

Purchasing order is available in units of 10 pieces. d d KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.

MI-A0801-10 MI-A0801-20 MI-A1201-10 MI-A1201-20 MI-A1201-30 MI-A2001-10 MI-A2001-20 MI-A2001-30 MI-A2501-30 MI-A2501-50 MI-A3201-30 MI-A3201-50 MI-A0802-10 MI-A0802-20 MI-A1202-10 MI-A1202-20 MI-A1202-30 MI-A2002-10 MI-A2002-20 MI-A2002-30 MI-A2502-30 MI-A2502-50 MI-A3202-30 MI-A3202-50 MI-A0803-10 MI-A0803-20 MI-A1203-10 MI-A1203-20 MI-A1203-30 MI-A2003-10 MI-A2003-20 MI-A2003-30 MI-A2503

-20D 8 12 20 25 32 10, 20 mm 130 10 MIS12-10D D10, 20, 30 mm 3 5 160 20 MIS12-20D 10, 20, 30 mm -X 30, 50 mm 190 30 MIS12-30D 30, 50 mm 300 10 MIS20-10D 20MIS 5 15 355 20 MIS20-20D Data 410 30 MIS20-30D 800 30 MIS25-30D 10 15 1000 50 MIS25-50D 1350 30 MIS32-30D 18 50 1650 50 MIS32-50D 10-11-9 9 Series MIW/MIS Construction: Double Finger Type (MIW) 8 12, 20 q y r !

Refer to Graph (10) based on horizontal mounting, a speed of 500 mm/s and load eccentricity of 50 mm. In Graph (10), find the intersection of a 30 mm overhang and load weight of 0.1 kg, which results in a determination of 16. 8-2-13 12 Series MXH Construction MXH6 (6) MXH10 (10) y @1 !7 w q!9 t !8 i !0 @0 @0 y @1 !6 w q !9 t !8 !

LH 0.2 d W W C B D E LY 4-LD MM Width across flats G LT NA NB Y X X Y S + Stroke LX B LS + Stroke ZZ + Stroke With rod boot h + l 10 f l e ZZ + l + Stroke (mm) Bore size (mm) A B a B C D 0 -0.018 0 -0.021 0 -0.021 0 -0.021 0 -0.025 0 -0.025 0 -0.025 d E F G GA GB J K LD LH LS LT LX LY M MA MM NA NB 0 -0.062 0 -0.062 0 -0.074 0 -0.074 0 -0.074 0 -0.074 0 -0.087 40 M8 x 1.25 10 17 45 23 60

Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable

When an electric current is applied to the molded coil r, the armature t is attracted to the core y, and through the push rod u, it pushes down the spool valve w. Then, port P and port A are connected. At this time, there will be gaps between the armature t and the core y, but the armature will be magnetically attracted to the core y.

Outlet: 60 Hz Outlet: 60 Hz 20 20 0.1 0.1 10 10 Outlet: 50 Hz Outlet: 50 Hz Return port Allowable operating range Return port Allowable operating range 0 0 0 5 10 15 20 25 30 0 5 10 15 20 25 30 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] 202 Thermo-chiller Basic Type HRSE Series Dimensions HRSE012/018/024-A-10/20/23 Ventilation air outlet Ventilation air inlet

: 10 8-6: 5; 8-8: 5, 8-10: 5 Max. operating frequency (cycle/sec) 8-6: 10; 8-8: 10, 8-10: 20 8-6: 3; 8-8: 3, 8-10: 2 Lubrication Not required Manual override Non-locking push type Enclosure Dusttight Coil rated voltage 100 VAC, 110 VAC, 200 VAC, 220 VAC, 24 VDC Allowable voltage range (%) 15 to +10% of rated voltage Coil insulation Class B or equivalent 50 Hz 5.6 Apparent Inrush 60 Hz 5.0

SY7120-02 SY7140-03 AS3001F-06 AS4001F-10 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 AS4001F-10 AS4001F-12 SY9120-03 SY9140-04 AS3001F-06 AS4001F-10 AS4001F-12 AN202-02 AN200-02 AN200-02 Conditions [When using SGP (steel pipe)] Conditions [When using SGP (steel pipe)] Body ported Base mounted Series CS1 SGP10A x 1 m AS420

1 C42FP-260S 1 IDF-S0529 1 IDF Series 9-2 9 2 IDX-OM-W011 10 L 10 L IDF4E/6E/8E/11E/15E1 10-1 ( ) 10-2 1.6MPaADH4000-04 IDF4E-**-L IDF6E-**-L IDF8E-**-L IDF11E-**-L IDF15E1-**-L N.O. () ) 0.151.6MPa ) 50L/min(ANR) IDF Series 10-1 10 1 IDX-OM-W011 10 L 10-3 Rc1/2 32 25 1) 2830Nm 30 (5) (22)(27) () () () 2) 3) 10-4 IDF Series 10-3 10 2 IDX-OM-W011 11 M 11 M IDF4E

Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with