Momentary change Pressure Set value P_1 H_1 t (ms) t (ms) Time
(at 80 mA load current) PNP: 1.5 V max.
RB RA W 4-O1 T Section a-a' Basic style (Through-hole): RZQB 2-RR 50, 63 Flat washer (Included) 4-HR 2-RR Flat washer (Included) b 2-N 4-O 4-N b' Section b-b' (mm) Bore size (mm) A B C D FB G H I J K L M N O1 O P Q RA RB RR RH T W E FA Z 32 100.5 82.5 14 22.4 12.5 9 M8 x 1.25 60 4.5 17 18 34 5.5 M6 x 1.0 9 Rc1/8 24.5 14 10 5.5 7 4.5 49.5 45 33 14 40 110 92 16 28 52 35 14 9 M10 x 1.5 69 5
9 Bumper Chrome molybdenum steel Clear hard anodized $3 NBR Plate A @0 O-ring Aluminum alloy $4 Clear hard anodized Carbon tool steel Plate B @1 C type snap ring for shaft Aluminum alloy $5 NBR Cushion seal @2 O-ring NBR 8-17-9 9 Series CYP Dimensions E Depth ED 4-MM Thread depth M T Y L T K PA 4-Counterbore dia B Counterbore depth C F 4-LD QW PB N Courtesy of Steven Engineering, Inc.-230
Coil None Z Continuous Duty Type: VK33E Varistor Varistor Exclusive use of VT317E is recommended for continuous duty with long time loading. Coil S Coil DC 6V 12V Caution Varistor Coil None Z 1. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC. 2.
angular acceleration after t seconds can be found as follows. t ( 1 ) 2 1 ( 2 ) C t tdt 2 When 0 t , rotation angle =0, so the integration constant is C=0. t t 2 1 2 1 2 thus, 2 t 28 - Auto switch type for rotary table The rotary table has a magnet mounted on its piston and an auto switch on the outside of the body to detect the piston position (table position).
Built in T-slots T-slots are provided on 3 faces of the body (except port face), allowing mounting for various brackets. (Not suitable for mounting the cylinder itself.) Non-rotating accuracy Bore Size (mm) Non-rotating accuracy 0.08 0.06 0.05 40 63 100 Note) Within allowable rotation torque.
Dimensions (mm) Electrical entry Conduit terminal: T Grommet: G Conduit: C B C D E G H J Z A Model Q R S T N X Y VV2CS2 22 50.5 44 41.5 66 99 77 49 20 24.5 28 4.5 38 17.3 34.5 56 VV2CS3 24 60 45.5 51 68 101 86.5 57 25.5 28.5 30 5.5 42 19.3 38.5 66 VV2CS4 26 68 47.5 58.5 70 103 94 57 25.5 28.5 30 5.5 42 20.8 41.5 74 6 Direct Operated 2 Port for Steam Series VCS VCS (for steam) 2 port solenoid
(mm) (mm) Rod end male thread Applicable bore size V W X U R S T Q Part no.
The voltage drop will occur due to the internal circuit of S, Z and T types (with energy saving circuits). Allowable voltage fluctuations should be within the range below.
Y L T K PA 4-Counter bore dia B Counter bore depth C F 4-LD QW PB N E depth EK Q + Stroke Z + Stroke A G Stroke adjustment screw Note 3) (inner cover) Plug Plug [P (port e)] [P (port c)] A A LW Plug Operating direction P (port a) P (port b) Auto switch mounting groove [P (port g)] 0.5 Note 2) 0.5 Note 2) Left Right Plug [P (port h)] HI HP H HL HG HT HS HB HA HB HA HG HT HI WB 4-J Depth JK
Y L T K PA 4-Counter bore dia B Counter bore depth C F 4-LD QW PB N E depth EK Q + Stroke Z + Stroke A G Stroke adjustment screw Note 3) (inner cover) Plug Plug [P (port e)] [P (port c)] A A LW Plug Operating direction P (port a) P (port b) Auto switch mounting groove [P (port g)] 0.5 Note 2) 0.5 Note 2) Left Right Plug [P (port h)] HI HP H HL HG HT HS HB HA HB HA HG HT HI WB 4-J Depth JK
We refer to these products as Z Products. These revolutionary products, whether simple or complex, provide P/A customers with superior performance and availability at a very affordable cost. Q P R O D U C T S Q Q 3 Q Series SYJ3000 Low Power Consumption: 0.5W (Current draw: 21 mA at 24VDC) Low power consumption enables direct operation by a PLC.
80 70 70 200 100 60 60 Air consumption Air consumption 150 50 50 75 40 40 100 50 30 30 20 20 50 25 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 1.0 2.0 3.0 4.0 5.0 6.0 Supply pressure [MPa] Supply pressure [MPa] Flow rate Characteristics Flow rate characteristics Supply pressure: 0.4MPa Supply pressure: 0.4MPa 100 90 100 90 Vacuum pressure [kPa] Vacuum pressure [kPa] 80 80 70 70 60 60 50 50 40 40
(Display pattern for 3rd, 4th, 5th, 8th and 9th digit from the left) Characters Q, X, Z, /, or cannot be displayed. (Display patter for 1st., 2nd., 6th., and 7th digit) Characters A to Z can be displayed (the same as the 3 digits on the right).
Series MGP Dimensions 4-MM depth ML 4-OA through 4-OB depth of counter bore OL Section XX HA:T-slot for hexagon bolt Section XX Z WA L 4-YY depth YL 4-NN through Section XX DL X0.02 X T R X0.02 X0.02 DA VB VA H 24 11 PW X U DB End lock mechanism non-locking type manual release ( ) XAH7 depth XL XAH7 depth XL GC XAH7 depth XL 2-P (plug) 2-P Q GA LL GB PB J K WB WA Z G PA + Stroke C + Stroke
How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are
DC12~24V 1. 2. 3. 4. 2 CE2 ()CEU2 CEU1 CEU5 0.1mm 2-1 CE2+CEU2 CEU2 CEU2 8 CE2+CEU1CEU5 3 CEU1CEU5 9 2-2 2-2-1 C E 2 B 40 100 Z N R 40 40mm ( mm ) H 50 50mm () 63 63mm 80 80mm J 100 100mm K (mm) 2 S 1 40 25850 25700 n n 50 25800 25650 63 25800 25650 80 25750 25600 100 25750 25600 (mm) 40 1200 950 50 1150 900 63 1150 900 80 1100 900 100 1100 850 10 2-2-2 CEU2 NPN
Height: 30 mm (LOW type), 100 mm (HIGH type) W H L2 T L1 [mm] Model C(L)KQG32 Compact cylinder type (Guide pin diameter: 12) C(L)KU32 Plate cylinder type (Guide pin diameter: 12) C(L)KQG50 (Guide pin diameter: 13) Clamping height LOW type HIGH type LOW type HIGH type LOW type HIGH type Clamping height H 30 100 30 100 24 54 Body thickness T 50 29 66 Body width W 50 70 66 Body length L1 127
Smooth Cylinder Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure 0.04 Minimum operating pressure MPa 12 16 0.03 20 25 32 40 0.02 50 63 80 100 0.01 0 0 10 20 30 40 60 50 70 80 90 100 Bore size mm (Measurement based on JIS B8377) Series CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 Stable operation possible even at a