P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N
It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8
Model AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 Model Note) Rated flow (l /min (ANR)) 300 750 1500 2200 3500 6000 12000 Port size (Nominal size B) , , , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.
Option J: With drain guide Bracket (Option) female thread T: With element service indicator Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35
) NE NN W WA WB WC Y YC ZB ZC ZD 0.12 5/18-18 0.50 0.60 0.51 90 0.95 0.28 3.39 0.09 1/8 NPT 0.25 5/18-18 0.62 0.72 0.47 90 1.17 0.28 3.47 0.09 1/8 NPT 0.41 3/4-16 0.88 0.85 0.51 45 1.50 0.31 3.91 0.09 1/8 NPT 0.50 1 1/4-12 1.19 1.20 0.81 45 1.91 0.59 5.11 0.12 1/4 NPT 3 Series NCM-A Dimensions ZB + STROKE LB + STROKE 0.50 W K A L ZC 2-ZD MM YC WA N KK UNF-2A B -0.003 0.000 PILOT Y WB D ACROSS
Logical Condition. 6-6 6.5.6 Select Signals to Drive Functions. 6-7 6.5.7 Setting Parameters. 6-7 6.5.8 Operation Check . 6-7 6.6 Simulation Mode.6-8 6.6.1 Entering the Simulation Mode . 6-8 6.6.2 Turn Signals On/Off. 6-8 6.6.3 Change Function Block Parameters. 6-8 6.6.4 Force Outputs On/Off. 6-8 6.6.5 Inactive Functions during Simulation Mode. 6-8 6.6.6 Exiting the Simulation Mode. 6-8 6.7
(ZS-24-A) Nil 10.0 to 101.3kPa 100.0 to 100.0kPa Nil F A Piping specifications Bracket B (ZS-24-B) W1: Rc1/8 01: R1/8 (with M5 female threads) T1: NPT1/8 (with M5 female threads) Reverse pressure two directions B R1/8, NPT1/8 Rc1/8 M5 x 0.8 female threads Panel mount (ZS-22-A) Rc1/8 E * M5: M5 x 0.8 (female threads) * C4: With 4 One-touch fitting * C6: With 6 One-touch fitting Wall mount
When a surge generating load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of applicable fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.
thread) Air 1.2 MPa 0.8 MPa Standard: 0.2 to 0.7 MPa, Low pressure use (0.2 MPa setting): 0.05 to 0.2 MPa 5 to 60C (No freezing) Relieving type 0.065 Ambient and operating temperature range Construction Weight (kg) Model Port size IN Model OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R1/8, M5 x 0.8 NPT1/8, M5 x 0.8 Rc 1/8 Symbol NPT 1/8 4 One-touch
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Symbol -X80, -X81 Main Value Double Acting Type 1 A N 06 5 1 4 VP31 1 D Z X81 Body size CE marking Nil Q None CE-compliant 4 6 8 1/2 1 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 2 Port size (IN, OUT port) Thread type Symbol VP3145 VP3165 VP3185 Port size Nil F N T D/DO/DZ/DU only Rc G NPT NPTF 03 04 06 10 12 14 20 Type of actuation X80 X81 Double solenoid Single solenoid External pilot Passage, Type
Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Note 3) A particulate generation test has been conducted in a vacuum environment of 10-Pa. a t e l u g c 2 Stainless steel linear guide & low particulate generation vacuum grease e i t n r a e p r a 0.0 10 0 20 10 w t i o o n L Operation cycles a t e l u g c e 1 i t n r a e Particulate generation from the linear guide unit has been reduced with the use of a stainless steel linear guide and
When the cylinder is used with a clamping mechanism, there is a danger of work pieces dropping out of it if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage. Therefore, safety equipment should be installed to prevent damage to machinery and human injury.
KEA12 KEB12 KEA06 KEB06 KEA08 KEB08 KEA10 KEB10 Without a push button guard With a push button guard Rc thread with a push button guard AS-F Example of circuit diagram (Residual exhaust of air cylinder) Model KEC-03 KEC-02 TMH Applicable tubing O.D. or connection thread 12, Rc 3/8 8, Rc 1/4 14 6 10 2 1 3 2 1 ASD Applicable tubing material Fluid Operating pressure range Ambient and fluid
Tubing Size Symbol Type Body Class Tubing outside diameter Metric size 4 04 6 06 8 08 10 10 1/8 03 3/16 05 1/4 07 3/8 11 1/2 13 3 J Inch size Table 2. AC Insert Pin. Holder Assy Model Number LQ-GPJ LQ-GPJ-N LQ-GPJS LQ-GPJS-N LQ-GJLQ-GJ-NLQ-GJSLQ-GJS-NLQ-GC Larger Diameter Tubing How To Order LQ GC Nil B None With bracket Type Table 1.
Body size Port size KKA3 S-01 M KKA3 P-01 M R1 / 8 R1 / 8 1 / 8 KKA3 S-02M 1 / 8 KKA3 P-02M R1 / 4 R1 / 4 KKA3 S-03 M KKA3 P-03 M R3 / 8 R3 / 8 KKA4 S-02M KKA4 P-02M R1 / 4 R1 / 4 KKA4 S-03 M 1 / 4 KKA4 P-03 M 1 / 4 R3 / 8 R3 / 8 KKA4 S-04 M KKA4 P-04 M R1 / 2 R1 / 2 KKA6S-03 M KKA6P-03 M R3 / 8 R3 / 8 KKA6S-04 M KKA6P-04 M 1 / 2 1 / 2 R1 / 2 R1 / 2 KKA6S-06M KKA6P-06M R3 / 4 R3 / 4 Built-in
3 Port Air Operated Valve VPA3145/3165/3185 Series How to Order 04 4 5 1 VPA3 Thread type VPA Air operated valve Nil Rc G NPT NPTF F N T Port size (IN, OUT port) Number of pilot 1 Single Symbol Port size Rc size VPA3145 VPA3165 VPA3185 Body size 03 04 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 06 10 12 14 20 8 1 2 1 Valve option Nil For ordinary pressure For vacuum and low pressure
ISG 1 03 1 0 0 W Mounting/Piping Caution Multipurpose pressure switch 1. Mounting is possible in either horizontal or vertical orientations. Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.