Bore size (mm) A B Hs Ht Hs Ht 125 1.5 1.5 69.5 71 69.5 69 140 1.5 1.5 76 77 76 76 160 1.5 1.5 85 88.5 85 85 180 7 5 95 97.5 95 95 200 9.5 7.5 106 108 106 106 9-9-22 23 Auto Switch Specifications Series CLS Proper Auto Switch Mounting Position for Lock Unit Auto switch Auto switch model D-M9N D-M9P D-M9B D-A90 D-A93 SMC CLS125 MODEL b a b a b Bore size (mm) 125 140 160 180 200 250 a 59 39
30.5 31.5 18.5 19.5 Grommet (Perpendicular) Reed switch Model Model 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 D-A90V 5 25.5 26.5 13.5 14.5 A B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø4 mm, Stroke: 5 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø4 mm, Stroke: 15 mm
Clean Series: 11 (Vacuum Suction Type), Bore Size: 10mm, Finger Option: Basic Style (Standard Type), Auto Switch: M9B (Solid State, Gen. Purpose, 2 Wire, Horizontal)
Clean Series: Vacuum Suction Type, Bore Size: 10mm, Finger Option: Basic Style (Standard Type), Auto Switch: Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: -, Number: -
Fittings & Tubing Air Cylinders Rotary Actuators How to Order 11 Vacuum suction type Clean series 11 M D HR 2 10 R M9B S 22 M D HR 2 10 R M9B S Number of fingers Copper, fluorine and silicone-free + Low particle generation Number of auto switches 2 2 fingers Nil S 2 pcs. 1 pc. 22 Vacuum suction type Nominal size 10 15 20 30 Auto switch Without auto switch (without magnet) Nil Connecting
With lock/226) 28 (64) Stroke 39 (4) 21 Motor cable (6) 70 58 47 6.7 17.5 Vacuum port Rc1/8 Note 3) 35 Encoder cable (7) Lock cable (4.5) Motor option B: With lock 8H9 ( ) depth 6 +0.036 0 13 n x 6.8 B 30 8H9 ( ) depth 6 +0.036 0 140 200 E C x 200 (= D) 25 Note 1) Please consult with SMC for adjusting the Z-phase detecting position at the stroke end of the end side.
A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
Available in four bore size options, series CJP2 includes a tiny, but powerful, 4mm bore size option making it the smallest double acting pin cylinder around. 6, 10 and 16mm bore sizes complete the range, all featuring extruded aluminium bodies, making them not only compact, but extremely light?weight.? Series CJP2 is auto switch capable and other options include rubber bumper cushions,
Note) A B A B Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8, F9 type 2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) For other model nos. 3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type.
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A9 D-M9 22 (24.5) A 2.8 0.5 W B ( ): Dimensions for D-A93 Bore size (mm) D-A9 A B W 6 10 16 36 11.5 9.5 (7) D-M9 A B W 29.5 5.5 3.5 (1) 29.5 9.5 7.5 (5) 33.5 9.5 0.5 33.5 13.5 3.5 40 15.5 5.5 20 41 15 13 (10.5) 45 19 9 25 40.5 16.5 14.5 (12) 45.5 20.5 10.5 Note) The above mentioned values are indicated as a guide for auto switch
Refer to page 378 for minimum stroke with auto switch. 32 is for B-series rod size only. CH2 H B B 50 100 CH D2 H B B 50 100 M9BW With Auto Switch With auto switch (built-in magnet) Port and cushion valve positions Refer to page 359.
C B A stroke A C 3) 2nd stage: B-A stroke operation Following the 1st stage, when the air pressure is supplied from the C port, the rod operates the B-A stroke. B B-A stroke B A C 4) Cylinder retraction When the air pressure is supplied from the B port, the rod retracts completely. B stroke A stroke A stroke or B stroke operation can be made individually.