SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F40-400-E"

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 800mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: K59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J51--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: K59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 220, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 470, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

0 o e AS-FM !4 u Meter-in type Meter-out type AS-D e Seal method: Face seal For G thread AS-T Meter-in type Meter-out type ASP !1 ASN r !2 AQ q w ASV y t AK i VCHC o ASR ASQ !0 u !5 e Meter-out type Meter-in type Component Parts No.

1 e !3 !4 o !0 !1 !2 e !3 !4 !5 !2 q !5 q t t r u u i i r y y w !6 w Meter-in type Meter-out type Meter-out type Meter-in type Seal method: Face seal For G thread e o !3 !1 !0 !4 !2 !5 q t u i r y !7 w Meter-in type Meter-out type Component Parts No.

8 e Hexagon socket head cap screw CXTM Carbon steel Hard chromium electroplated Cylinder tube Aluminum alloy Hard anodized !

(ANR) c V -~ AM~4S0 E V ;;2 1 -E t~ AM~350 ~ ~ 2 ~05 -tV 'ct! AM~2S0 1. Select the point of contact A of inlet pressure and max. air flow capacity in the graph. V j.--v v V AMl,so 0.2 Ij.--~ V I 2.Select the type whose max. air flow capacity is over that point; AMH650. 0.2 0.4 0.6 0.8 1.0 tnlet air pressure MPa SeriesAMH How to Order .

MSQ Angle adjustment Range Figure 5 MSZ MSZ CRQ2X MSQX ad a ge ju Cl lt MRQ an st bo oc t r m nd en g k en tm wi in e us 10 10 se t r st on dj a ju an r on ti ot ad iti ta os ge at p ro er y nt io e b C e b n y is e ge n ad w d k an c ju lo t r C st in en g m bo st lt ju b ad M 0 ax 19 im e u ng m ra ro n ta tio Center position adjustment Table 2 R: Clockwise adjustment L: Counterclockwise

f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .

Actuator driving system Inside of clean room w t e q r t q Cylinder relief port piping w Solenoid valve exhaust piping e Breathing piping of regulator r Drain piping t Exhaust Cleaner for Clean room/AMP series Cylinder relief port piping Series 10-/12-/21(atmospheric release type) Connect the relief port piping with the dedicated duct piping installed outside the clean room or with the exhaust