Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9BV,
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 mm, Stroke: 10 mm, Rod End Thread: B (Without Thread), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 10 mm, Rod End Thread: B (Without Thread), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 12mm, Stroke: 10mm, Rod End Thread: Female, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 25mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 10mm, Body Option: Standard, Locking Direction: B (Retracting Stroke Lock), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07 to 1, Specification: Built-in magnet,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 11, Gripping Force (Open Side at 0.5 Mpa)(N): 17, Environment, Applications: Standard, Additional Function: With Linear
Magnet: Built-in, Mounting: Through Hole, Bore Size: 25mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 10mm, Body Option: Standard, Locking Direction: Retracting Stroke Lock, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches
Bore Size: 10mm, Action: D (Double Acting), Finger Position: Standard, Body Option: Basic, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X5 (Fluororubber Seal)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 3.07509 lb
The MHZ2 series is a standard type parallel air gripper, taking the place of the MHQ*2 series. A linear guide provides high rigidity and high accuracy. MHZ2 can operate under higher pressure even at a larger holding point and overhang. High degree of mounting precision is achieved and mounting repeatability is improved. Long stroke type parallel gripper, Bore sizes from 10mm to 25mm available
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25