SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2WA20-50DCMZ-A96VL"

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 0.3m Cord Length, M12

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Rod End Male Thread, Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, Lead Wire or Prewired Connector: 5m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: A96V--Reed, 8VDC max, LED, Vertical, Lead Wire: L (3m)

Sensor Type: Contacting, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Lead wire length(m): 3, Applicable load: IC circuit

Model: MSQ, Precision: Basic, Size: 10, Suffix: Adjuster Bolt, Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -

Model: MSQ, Precision: Basic, Size: 50, Suffix: Adjuster Bolt, Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -

Model: MSQ, Precision: Basic, Size: 30, Suffix: Shock Absorbers, Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 20, Valves: Not Provided, Allowable Kinetic Energy(J): 0.574, Torque(N⋅m): 3.14,