SMC Corporation of America
Elite Part Number Search
Search Results "CNA2D50-300-D"

BM2-032 BM2-040 D-C7, D-C8, D-H7 D-B5, D-B6, D-G5 D-A3A, D-A44A, D-G39A, D-K39A BM2-020 BM2-025 BA2-032 BA2-040 BA2-020 BA2-025 BM3-032 BM3-040 BM3-020 BM3-025 Caution Mounting Type and Accessories 1. Be careful of the snap ring springing out. When replacing the rod seal, take care that the snap ring does not spring out while you are removing it.

Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.

ZS-33-F D NPN Analog 4 to 20 mA E PNP Analog 1 to 5 V Analog 0 to 10 V*3 + ZS-33-D F PNP Analog 4 to 20 mA *3 1 to 5 V or 0 to 10 V can be selected by pressing the button.

Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d

Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d

Flow rate (l/min (ANR)) Inlet pressure (MPa) ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 Flow rate (l/min (ANR)) Inlet pressure (MPa) ARP40(K) ARP40(K) Rc1/2 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35

N213 aOSilrtr 3 way.3 port sotenoid vatve NVZseies Rubber Seal Model 100/300/500 Low Power Consumption 1.8 WDC Compact Size, Large Flow Capacity Cv 0.05 0.5 High Speed Response Time -15 mSec (NVZ 100) Built-in One-Touch Fitting Manifolds Avaihbb Individual or Manifold Mounting Variat ions of C L Kl tmrn"..

Type of actuation Plug Plug JIS symbol 3-2-1 Series VK3000 How to Order Electrical entry G: Grommet (Lead wire length: 300 mm) D: DIN terminal H: Grommet (Lead wire length: 600 mm) DO: DIN terminal (Without connector) For connector part number, refer to page 3-2-11.

Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3

Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

VH600 VR Option VH300 VH410 VH VH300/400 Bottom ported VH210 VHS VH200/300/400 Panel mounted All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.

400 500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 Flow rate l/min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30 Downstream pressure MPa Downstream pressure MPa 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 Flow rate l/min(ANR) Flow rate l/min(ANR) Pressure characteristics

/ When lubricated, use turbine oil #1(ISO VG32) VH600 Optional specifications VH300 Bottom porting VH410 VH300, 400 Panel mount VH200, 300, 400 VH210 Different P port location* All models 1(P) port is located on handle side.

Dimensions [Separately installed power transformer] C E IDF-TR7000-8 G B D 4 x F A Specications/Dimensions in (mm) Transformer Applicable dryer Capacity Type Inlet voltage Outlet voltage A B C D E F G Weight 14.2 (360) 21.3 (540) 15.7 (400) 10.2 (260) 11.8 (300) 0.43 (11) 1.18 (30) 207 lb (94 kg) IDF-TR7000-8 IDF100FS 7 kVA Three-phase Compound winding 220, 240 380, 400, 415 440 V (50/60

0 50 100 150 200 250 0 0 50 50 100 100 0.5 s 0.5 s 150 150 1 s 1 s 200 200 2 s 250 250 2 s 5 s 5 s 300 300 421 IZS40/41/42 Series Note) Static neutralization features are based on the data using the charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S.

Exampte)26NW o f "f able 'pllonaISpeci Ica rIons comb' matlon T Filter 1Regulator applicable model Optional specifications 2 6 8 C J N W Description Symbol Auto drain D D C 1 AW2001 AW3001 AW4001 I Differential pressure type auto drain D ActessOlY Float type auto drain(N.O.) 0 (Optioo) Float type auto drain(N.C.)

(max. 20 stations) 3 SY3000 5 SY5000 Connector mounting position A, B port size Symbol Mounting position U U side SY5000 SY3000 D D side Symbol Port size 4 One-touch fitting C4 Symbol Port size 4 One-touch fitting C4 6 One-touch fitting C6 Mixed M 6 One-touch fitting C6 Valve stations 8 One-touch fitting C8 Mixed M Stations Symbol Note Single wiring specifications (up to 16 solenoids are

Symbol Applicable stations Mounting position U side D side Both sides M Special specifications 2 to 10 stations 2 to 10 stations 2 to 16 stations D U B Indicate special specifications separately on a manifold specification sheet. Note 2) The number of blanking plate assemblies is also included.