SMC Corporation of America
Elite Part Number Search
Search Results "CQ2BH40-PS"

Kit components 40 MGF 40-PS Items 19 through 23 from the table above. 63 MGF 63-PS 100 MGF100-PS 4 Series MGF Dimensions 40 MGF40 Scale: 50% 4-M8 x 1.25 through 100 120 90 9.5 36.5 + Stroke 8 46 + Stroke 7.5 18.5 2-Rc 1/8 port for extending cylinder Breathing hole for guide (with element) When the cylinder is extended 38 Port for retracting cylinder M5: T-slot for hexagon bolt 4-M8 x 1.25

M ount the w at er separat or t o the pl ace w i t h the hi ghest pressure i n used pneum at i c ci rcui t . ( H i gh pressure hel ps l i qui di ze t he m oi st ure. ) M ount t he regul at or t o t he out l et si de of t he w at er separat or( j ust af ter secondary si de) .

Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 SMC Product Conforming to International Standards national Standards you to comply with EC directives and CSA/UL standards.

(Heat source) TS Level switch Temperature sensor (For compressor discharge) Fluid level indicator Pressure sensor (For low-pressure refrigerant gas) PS PS TS Temperature sensor (For discharge) Temperature sensor (For compressor intake) Compressor Pressure sensor (For discharge) Circulating fluid outlet TS Circulating fluid circuit Refrigeration circuit Drain port Refrigeration circuit Circulating

Temperature sensor (For discharge) Heat exchanger Heating valve control Pump Pressure sensor (For low-pressure refrigerant gas) Pump drain port PS TS Temperature sensor (For compressor intake) Compressor Refrigeration circuit Circulating fluid circuit * This circuit construction of the position of the parts may be different from actual product.

return) TS HECR Temperature sensor (For compressor intake) Users equipment (Heat source) PS TS Drain port DC inverter compressor HEC Temperature sensor (For discharge) Pressure sensor (For discharge) Circulating fluid outlet HEB Refrigeration circuit Circulating fluid circuit * This circuit construction of the position of the parts may be different from actual product.

B E Resin tank Facility water circuit HEC User's equipment (Heat source) TS Level switch HEB Temperature sensor (For compressor discharge) Fluid level indicator Pressure sensor (For low-pressure refrigerant gas) HED PS PS TS HEA Temperature sensor (For discharge) Temperature sensor (For compressor intake) Pressure sensor (For discharge) Circulating fluid outlet TS IDH DC inverter compressor

Contents 6 10 15 CJPB6D-PS Set of nos. above !8, !9, @0 CJPB10D-PS CJPB15D-PS No. !8, !9 and @0 are one seal kit.

Indicator Unit (LED) Description and Its Function SI unit (DeviceNet) SI unit (PROFIBUS-DP) Input block 1 3 5 7 PWR 0 2 4 6 TM TM PWR(V) RUN PWR(V) MOD/NET PWR ADDRESS 1 H L 0 SETTINGS DIA BF FB FB PS PS Description Description Function Function Description Function PWR(V) ON when solenoid valve power supply is turned ON. ON when sensor power is turned ON.

Contents 6 10 15 CJPB6D-PS Set of nos. above !8, !9, @0 CJPB10D-PS CJPB15D-PS No. !8, !9 and @0 are one seal kit.

Contents 125 CS1N125A-PS Set of above nos. $6, $8, $9, %3, %4, %7 140 CS1N140A-PS 160 CS1N160A-PS Since the lock section for Series CNS is normally replaced as a unit, kits are for the cylinder section only. These can be ordered using the order number for each bore size. Seal kit includes $6, $8, $9, %3, %4, %7.


Old product:
Rubber bumper: CG1N□-PS
Air cushion: CG1A□-PS
Refreshed product:
Rubber bumper & air cushion: CG1N□Z-PS (the number in the “□” indicates the cylinder I.D.)
Note 1) There is no seal kit part number for bore sizes ø50 and larger because the products cannot be disassembled by the customer.

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Magnet: None, Mounting: B [Through Hole (Standard)], Type: H (Air-hydro), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: M (Rod End Male Thread)

Magnet: None, Mounting: B [Through Hole (Standard)], Type: H (Air-hydro), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm

Magnet: None, Mounting: B [Through Hole (Standard)], Type: H (Air-hydro), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm

Magnet: None, Mounting: B [Through Hole (Standard)], Type: H (Air-hydro), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm

Magnet: None, Mounting: B [Through Hole (Standard)], Type: H (Air-hydro), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: M (Rod End Male Thread)