Lube ALD600-l06 to 10, ALD900-l12 to 20 At the terminal of an air pressure line in which a D.P. Lube is used, install a strainer (filtration rate of 5m) upstream with a metal seal solenoid valve, which is susceptible to dust.
Install an after-cooler, air dryer or water separator, etc. Air containing excessive drainage can cause malfunction of valves and other pneumatic equipment. To prevent this, install an after-cooler, air dryer or water separator, etc.
Black (DC) Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option. Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops.
Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60C. IDU3D to 6D: 60C IDU8D to 37C1: 55C IDU55C, 75C: 50C Series IDF Can accommodate an inlet air temperature of 40C System efficiency is improved by using a high performance heat exchanger.
In case of an end lever type with locking mechanism, do not apply an external force from the opposite side when the lever is locked. Lower the cylinder before adjusting the conveyor or moving the pallet. 2. Do not let your hand become caught when operating the cylinder. The lever holder goes up and down while the cylinder is in operation.
Spacers are used to fix the stroke adjustment unit at an intermediate stroke position.
For connection with a load having an external support/guide mechanism, select an appropriate connection method and perform careful alignment.
M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table 3 Find the allowable static moment Ma (Nm).
Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines.
Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.
The unit body can be fixed by tightening four holding bolts evenly at an arbitrary position. However, there is a possibility that the adjustment mechanism will be tilted due to high impact energy. Since the holder mounting bracket for adjustment is available as an option for -X416, X417, we recommend that you use it.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1. The product is provided for use in manufacturing industries.
The unit body can be fixed by tightening four holding bolts evenly at an arbitrary position. However, there is a possibility that the adjustment mechanism will be tilted due to high impact energy. Since the holder mounting bracket for adjustment is available as an option for -X416, X417, we recommend that you use it.
Install an air dryer or after cooler on the upstream side of the pressure release 3 port valve because air containing excessive drainage may cause malfunction. SA VA SA Model VHS20 VHS30 Effective sectional area (mm2) (Cv) 5 (0.27) 5 (0.27) Caution VA 3. Do not apply negative pressure. It may result in malfunction. 1. Install an air filter of 5 mm filtration on the inlet side. 2.
They do not guarantee an actual fixed range (expect approximately 30% dispersion).
Then, give an additional half rotation of screw. After that, incline the lever by 90 and confirm that the indicator light is not on and does not show either red or green.
This clears the unit when an abnormality occurs and clears the accumulated flow display to "0". UP Button ( Button) U P Output (OUT1) Indicator/Green Use when increasing a setting value. SET Lights up when OUT1 is ON. It also blinks when an overcurrent error occurs on OUT1. OUT2 OUT1 SET Button ( Button) DOWN Use when changing a setting value or any of the modes.