100 N JCM CDG3 L 100 M9BW N 25 C With auto switch CM2 With auto switch (Built-in magnet) CM3 Made to Order For details, refer to page 366.
SPECIFICATIONS Model ZSE4-00-25(L)-X105 ZSE4-00-26(L)-X105 Model (N)ZL112 (N)ZL112-G (N)ZL112-E (N)ZL212 Nozzle Diameter 1.2mm 1~5V + -5% FS load impedence 1k 1.2mm x 2 Output Specification 1 output, NPN open collector 30V 80mA Max Suction Flow 100 l/m (ANR) 200 l/m (ANR) 126 l/m (ANR) Air Consumption 63 l/m (ANR) Fluid Air Max Vacuum Pressure -84kPa (-12PSI) -12PSI Setting PressureRange
70 100 200 300 10 30 50 70 100 200 300 Eccentric distance l (mm) Eccentric distance l (mm) Selection graph to 700mm/s Selection Example: Vertical Upward Mounting Solid line: Operating pressure 0.4MPa or more 100 50 Selection conditions Mounting: Vertical upward (lifter) Maximum speed: 500mm/s Load mass: 40kg Eccentric distance: 80mm Load mass m (kg) Refer to graph based on vertical mounting
W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L. W L Mounting hole W Intermediate support mounting hole L L Distance between Load and Supports Mounting hole 140 130 25 120 CY3B CY3R 110 100 CY1S 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed.
W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L. W L W Mounting hole Intermediate support mounting hole L L Distance between load and supports Mounting hole 140 130 25 120 110 100 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed.
500] 500 L/min(PFMC7102) 29 [F 1] [ 1000] 1000 L/min(PFMC7202) [ 25] 25 L/min(PFMC7501) [ H_1] OUT1 [ 50] 50 L/min(PFMC7102) [ 100] 100 L/min(PFMC7202) [ CoL] OUT1 [SoG] ONOFF [ oU2] OUT2 2 [ HYS] [ 2ot] OUT2 2 [ 2_P] [ 250] 250 L/min(PFMC7501) [ P_2] OUT2 2 [ 500] 500 L/min(PFMC7102) 37 [F 2] [ 1000] 1000 L/min(PFMC7202) [ 25] 25 L/min(PFMC7501) [ H_2] OUT2 2 [ 50] 50 L/min(PFMC7102) [
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-04 {Rc1/2} FGH200-04 {Rc1/2} FGH300-04 {Rc1/2} 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) 0.01 0.01 0.01 0.005 0.005 0.005 0.001 10 30 50 70 100 0.001 10 30 50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-06 {Rc3/4} FGH200
g LCPPBT()HNBR() FKM()SiAuSUS()304 AWG26 0.50 mm 1.00 mm PVC 3.5 -56No.PF-OMJ0005CN-I CO2 3[V]12[mA] (15V) (420 mA) [mA] [V] [L/min] [L/min] PFM710--C/E 10(5) PFM710--D/F 10(5) PFM725--C/E 25(12.5) PFM725--D/F 25(12.5) PFM750--C/E 50(25) PFM750--D/F 50(25) PFM711--C/E 100(50) PFM711--D/F 100(50) ( )CO2 ( ) CO2 () 25[L/min] 10[L/min] [L/min] [L/min] 50[L/min] 100[L/min] [L/min]
: U 0.3 C 0.5 W W D 0.7 0.1 (100) (100) 0.3 600 500 400 300 1000 1100 900 800 700 200 100 0 Cylinder stroke (mm) U 92 85 0.5 Center trunnion: O Head side trunnion: U 77 71 0.7 Series CS1 only W W 57 53 0.3 T 43 40 0.5 35 33 0.7 Foot: L Rod side flange: F Head side flange: G (100) (100) 0.3 L (100) (100) 0.5 W W W F (100) (100) 0.7 83 77 0.3 G 63 58 0.5 52 48 0.7 Foot: L Rod side flange
: L Rod side flange: F Head side flange: G (100) (100) 0.3 L (100) (100) 0.5 W W F W (100) (100) 0.7 (100) (100) 0.3 G 92 86 0.5 77 71 0.7 6-10-4 5 Cylinder: Standard/Non-rotating Type Double Acting, Single/Double Rod Series C76 32, 40 How to Order CJ1 C Double acting Single rod K R2 76 J D E C A 32 100 CJP CJ2 C Double acting Double rod W 76 D E 32 100 C JJ B CM2 Auto switch mounting type
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
200 VAC specification] Terminal block K L H M N J 4-13 P [200 VAC specification] Power cord outlet (17) [100 VAC specification] Power cord (mm) A B C D E F G H J K L M N P Q Port size Model IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E 69 101 270 32 21 330 413 38 150 3/8 226 410 240 15 51 232 138 24 327 125 67 304 33 73 31 36 154 21 330 473 1/2 13 453 283 275 498 455 15 270 31 80 230 32 15
l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than
Connector Sensor cable length With connector Without connector
W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L. W L Mounting hole W Intermediate support mounting hole L L Distance between Load and Supports Mounting hole 140 130 25 120 110 100 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed. According to 2.
W L Mounting hole W Intermediate support mounting hole L L Distance between Load and Supports Mounting hole 140 130 25 120 110 100 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed. According to 2.
Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .
Spring and pneumatic locking type Air pressure supply Air pressure exhaust Air pressure exhaust Air pressure supply Unlocked state Locked state Brake piston is operated by air pressure and spring force. 9-2-8 Fine Lock Cylinder Double Acting, Single Rod Series CLG1 20, 25, 32, 40 How to Order CL Without auto switch CLG1 100 L E N 25 CL1 MLGC CDLG1 With auto switch H7BW 100 L E N 25 CNG Built-in