Operating press: 0.5 MPa Bore size: 100 Output: 3850 N Operating press: 0.8 MPa Bore size: 80 Output: 3850 N Equivalent output force 6. When the hydraulic pressure of an air-hydro unit must be raised. 7. When the pressure must be raised in an explosion-proof environment. 8.
CRJ1 CRJ05 Model 30 25 Fr Allowable load (N) 25 20 FS(a) 25 20 FS(b) 6 5 Pinion gear Output shaft size (mm) Stopping the pinion gear by having it strike against the flat surface of the piston eliminates backlash.
Implement countermeasures by installing aftercooler or air dryer, or water separator, etc. The air including excess drain may result in a malfunction of valves and other pneumatic equipment. Implement countermeasures by installing after-cooler or air dryer, or water separator, etc.
M O U N T I N G S Full range of NFPA accessories.
(n 2) 2 20 + 35 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9 5 20 CHQ 55 (n = 2, 4, 6) Note 3) (n 2) 2 55 + 35 (n 2) (n = 2, 3, 4, 5) 20 + 35 D-M9W 10 20 55 CHK (n = 2, 4, 6) Note 3) (n 2) 2 60 + 35 (n 2) (n = 2, 3, 4, 5) 25 + 35 D-M9A 10 25 60 CHN (n = 2, 4, 6) Note 3) (n 2) 2 50 + 35 (n 2) (n = 2, 3, 4, 5) 15 + 35 D-A9 5 15 50 CHM CHM (n = 2, 4, 6) Note 3) (n 2) 2 35 + 35 (n 2) (n = 2,
Winding direction Port size Knob lifting force M5 10-32/UNF 1 to 1.5 N Sealant tape Expose approx. 1 thread 1/8, 1/4, 3/8, 1/2 3.5 to 4 N 4. Do not rotate the product by the indicator part. Use a wrench for mounting the product. Otherwise, it may cause damage to the product. 601
Only tighten by hand. (0.4 to 0.6 N-m) 3. The excessive stress on the cable connector will not be able to satisfy the IP65 rating. Please use caution and do not apply a stress of 30 N or greater. Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tightened.
NBR, for example, is a material that can suffer deterioration caused by residual ozone.
However, the piston speed at this time should be adjusted to the minimum speed. 15 65 10 (n = 2, 4, 6 ) 65 + 50 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) 15 + 50 n 2 2 D-B5 D-B6 15 75 10 (n = 2, 4, 6 ) Mounting 75 + 55 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 Caution D-B59W 20 75 15 (n = 2, 4, 6 ) 1.
M5 x 0.8 (Piping port) 10 10 7 7 14 M3 x 0.5 28 (Piping port) 1476 4/5 Port Air Operated Valve SYJA5000 Series SYA How to Order SYJA SYJA VZA A, B port size Bracket VFA One-touch fitting for 6 C6 One-touch fitting for 4 M5 x 0.8 C4 M5 With bracket F Nil Without bracket VFRA *The bracket is not mounted. *2 position single only VPA4 SYJA SYJA5 20 1 M5 Body ported VZA VTA SYJA5 40 2 Base mounted
M5 x 0.8 (Piping port) (Piping port) With fiflter (80 mesh) 21.5 R1 P 8.5 6 6 2-1.8 (Bleed port) 17 17 15 R2 21 With fiflter (80 mesh) 24 32 45.5 3 position closed center/exhaust center/pressure center SYJA5 20-M5 3 position closed center/exhaust center/pressure center SYJA5 40-01 3 4 5 3 4 5 28 2-4.3 2-M5 x 0.8 2-M5 x 0.8 37.5 23 (Pilot port) (For mounting) (Pilot port) A B 11 20 23 5 3
N Symbol Electroless nickel plated Control type If more than one option is required, write option part numbers in the order of S, N.
(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.
The tensile stregth of the power cord is 49 N, and pulling it with a force greater than this can cause failure. Hold by the body when handling. Socket 3.
A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud. M5 x 10 DIN913-45H VP4 12 2 8 VZS G 1/4 DIN/ISO228/1 M5 Drive flange face VFS VS4 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 VQ7 1.5 3 EVS VFN The solenoid valve can be attached with 2 mounting bolts.
48(22) 2 Position single Base mounted type SYJA3240-M5 51(25) 2 Position double 1.8 (0.1) SYJA3340-M5 M5 0.8 M3 0.5 3 Position closed center 54 (28) SYJA3440-M5 3 Position exhaust center SYJA3540-M5 3 Position pressure center SYJA3130 22 4 Port base mounted type (For manifold) 2 Position single SYJA3230 25 2 Position double Note1) Note1) M3 0.5 M5 0.8 1.2 (0.067) M3 0.5 SYJA3330 3 Position
In the case of the return to origin by pushing force, additional force will cause displacement of the origin position since it is based on detected motor torque. 6. Do not remove the nameplate. 7. Operation test should be done by low speed. Start operation by predefined speed after confirming there is no trouble. 8.
The circulating fluid is sent to the heat exchanger by the pump, and is controlled to a set temperature by the refrigeration circuit, to be discharged to the customer system side again by the thermo-chiller.