Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Applicable model Minimum operating flow rate [L/min] HRS-BP005 HRSH090-ll-l 20 r t r e q To circulating fluid outlet r t w r Parts List No.

8.4 NO X X PE NC 30.5 30.5 116.1 98.6 91.6 91.6 2(A) 3(R) 66.8 57.6 1(P) 43.8 43.8 34 34 71 (P port) Rc 1/2, 3/4, 1 (R port) Rc 1/2, 3/4, 1 (A port) Rc 1/2, 3/4, 1 5-5-12

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max.

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

(t) is given by the graph. Then, the charge time (T) for a 100 L tank: With the pressure increase ratio from 2.0 to 3.0, the charge time of 147 58 = 89 sec. (t) is given by the graph. Then, the charge time (T) for a 10 L tank: T = t x = 3.2 x = 32 (s). V 10 T = t x = 89 x = 89 (s).

End plate e Body r Vacuum sensor unit t Nozzle y Diffuser u Other than vacuum switch P397110 Detent plug i Vacuum switch specifications P397176 Lead wire cover 13-7-11 12 Series ZL Dimensions: Series ZL212 Pressure supply port Rc 1/8 Vacuum port Rc 3/4 Exhaust port 76 P Standard ZL212 40 V 54 125 Label 188 61 P Port exhaust ZL212P V Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

D I N 'E Terminal 'T Conduit Temlnal 'H 24' Lead hing 01 %'(AXSrd.) t M5 NOM 10-32 ilanual Overrida _Recessed, Nonlocking (Std.)

D I N 'E Terminal 'T Conduit Temlnal 'H 24' Lead hing 01 %'(AXSrd.) t M5 NOM 10-32 ilanual Overrida _Recessed, Nonlocking (Std.)

The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1013)/t /min(ANR) V: Inner volume = cm3 P: Absolute pressure = {Operating pressure (MPa) + 0.1013} t: Operating time = s CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.

Plate mounting support bracket Body mounting side support Auto switches mountable (both sides) Types of Units and Parts Type of units and parts Type of units Type of parts Single units P.1 to P.9 Combination units P.11 to P.18 Set parts P.11 to P.14 Parts P.16 Spare parts P.4 & 5 Optional parts P.2 Catalog pages Parts for combination units.

Bore size NTJ-010A NTJ-006A 8 6 M3 x 0.5 2.4 5.5 6.4 5.5 6.5 M3 x 0.5 6 12.5 M4 x 0.7 3.2 7 8.1 7 8.5 M4 x 0.7 8 14.5 NTJ-015A 10 M5 x 0.8 4 8 9.2 10.5 M5 x 0.8 16.5 10 9 (mm) Standard C D E F B A J K L M N O P G H I Bore size 8 6 M2.5 x 0.45 13 7 7 10 9 19 3 5 4 9 3.5 8 7 5.3 24 M3 x 0.5 13 7 8 11 10 21 3 6 5 11 4.5 10 8 5.3 25 10 13.5 M3 x 0.5 7 8.5 11.5 10.5 22 3.2 6 6 12 5 11 8.5 5.6

M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Plug connector Large flow capacity Standard V14:13(27) V14A:16(30) V14:12(26) V14A:15(29) Large flow capacity V124A Note 1) 1 2 Flow characteristics 2 3 V100 Valve model C[dm3/(sbar)] 0.037 0.076 0.054 0.099 C[dm3/(sbar)] 0.054 0.099 0.037 0.076 b 0.11 0.070 0.35 0.23 b 0.35 0.23 0.11 0.070 Cv 0.0080 0.016 0.015 0.024

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: -