/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .50160 lb
, 2 COLOR DISPLAY DIGITAL PRESSU, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 0.89287 lb
/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .69045 lb
/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .64151 lb
/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 1.20173 lb
M18 x 1.5 25 to 1800 135 102 19 42 22 18 44 44 3/4 75 192 20 3 156 40 53 145 40 225 19 15 100 80 Rod series Tolerance (mm) B-series rod C-series rod Bore size (mm) Bore size (mm) TDe9 TX E E MM A MA D K G H ZZ MM A MA D K G H ZZ 32 32 34 M16 x 1.5 25 22 18 7 14 55 207 0 0.3 0.040 0.092 0.025 0.064 40 40 40 36 M20 x 1.5 30 27 22.4 9 19 60 212 18 M16 x 1.5 25 22 7 14 55 207 0.025
or less 50 mA or less Weight 45 g Maximum load current: 80 mA Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V 2 outputs Resistance Output Note 5) specifications NPN open collector (PF2W300, PF2W330) Switch output Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (with load current of 80 mA) 2 outputs PNP open collector (PF2W301
a CHM A MA a Cushion adjustment screw Air release R (max.)
Sensor power supply RHC Preset output Output signal type Compare/Hold/One-shot (100 ms fixed pulse) Preset output configuration MK(2) 5 ms or less Output delay time NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power
Sensor power supply RHC Preset output Output signal type Compare/Hold/One-shot (100 ms fixed pulse) Preset output configuration MK(2) 5 ms or less Output delay time NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power
Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor 1 Power supply voltage: 1.5 V Power supply current for sensor 2 Max.110 mA (However, the total power supply current of 4 input is 440 mA or less maximum) The total power supply current when used as an IO-Link device is 200 mA or less maximum Display accuracy (Linearity) 5.0%F.S.
Note 2) 52-SY9000 has no bracket. 5 7 9 52-SY5000 52-SY7000 52-SY9000 Thread type Type of actuation Nil F N T Rc G NPT NPTF 2-position single 2-position double 3-position closed centre 3-position exhaust centre 3-position pressure centre 1 2 3 4 5 A, B port size (Body ported type) Piping type Port size Applicable series Symbol 01 C4 C6 C8 N3 N7 N9 02 C8 C10 N9 N11 02 03 C8 C10 C12 N9 N11
Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less
A voltage drop may cause the air dryer to stop operating. *1 Select an earth leakage breaker with a sensitivity of leak current of 30 mA and a rated current of 10 A. <200 VAC> Connect the power supply to the terminal block. Install an earth leakage breaker*2 suitable to each model for the power supply.
31 32 35 30 30 03 3F 38 0D Answer 25.0 deg.C. 31 Temperature setting (without writing FRAM) No 02 31 32 35 30 30 03 3F 38 0D 06 0D Set at 25.0 deg.C 32 Reading internal sensor No 05 32 33 32 0D 02 32 32 35 30 32 03 3F 3B 0D Answer 25.02 deg.C 33 Reading external sensor No 05 33 33 33 0D 02 33 33 30 30 32 03 3F 38 0D Answer 30.02 deg.C 34 Reading alarm status No 05 34 33 34 0D 02 34 30 38
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) Back pressure: 0.5 MPa Supply pressure: 0.5 MPa IR2000-02 IR2000-02 IR2000-02 ARJ 0.204 0.5 0.2 AR425 to 935 Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure P2 (MPa) 0.4 0.202 Set point 0.15 ARX 0.3 0.200 AMR 0.1 0.2 0.198 ARM 0.05 0.1 0.196 ARP 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0
-08 AS2200-02 100 200 50 100 0 0 SV100 ANA1 -C08 T0604 SV200 ANA1 -C10 T0806 200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed
Applicable bore size B (C) (D) d H NT-02 20 13 (15.0) 12.5 M8 x 1.25 5 NT-03 25, 32 17 (19.6) 16.5 M10 x 1.25 6 NT-04 40 22 (25.4) 21.0 M14 x 1.5 8 Part no.
To use the power of the product, the total load current must be 200 mA or less. 2.2 Communication specification HRLE Series 2-2 HRX-OM-Z015 Chapter 2 Contact input / output communication Table 2-4 Contact input/output communication terminal number PIN No.
Adaptor connection thread Symbol Pad dia. 1 02 to 08 B5 2 10 to 16 3 20 to 32 B8 4 40, 50 T 2 ZP B5 [qAdaptor] R S ZP 04 A5 [wR type adaptor] Symbol S Pad dia. 02 to 16 L 20 to 50 With Buffer ZP R 16 K20 A10 06 UGN [Pad model no.]