Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ Refer to page 8-12-24 for details on other applicable auto switches than listed above.
For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an
For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 63MM MYC/MY1C DBL-ACT AUTO-SW, ACTUATOR, MYC GUIDED CYLINDER, PE, 63MM MYC/MY1C DBL-ACT AUTO-SW, 46.29707 lb
For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an
For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an
Variation: D (2-step Control, Single Acting/Bellows Seal, O-ring Seal), Flange Size: 40, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: A93 (A93--Reed, DC Volt, AC Volt, LED, Horizontal), Lead Wire: L (3m), Number of Switches, Mounting Position: A (2 pcs, Valve Open/Closed)
Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.
Indicator light Lead wire length (m) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Auto switch model Special function Type Load voltage AC DC Wiring (Output) Electrical entry Pre-wire connector In-line Perpendicular Reed switch 3-wire (NPN equivalent) IC circuit A96 A96V 5 V Grommet Yes 2-wire 24 V A93 12 V 100 V Relay, PLC A93V 3-wire (NPN) 3-wire (PNP) M9N M9NV IC circuit 5 V, 12 V M9PV
However, please contact SMC for water-resistant products of 20 and 25. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.
B64 M9NW Relay PLC Yes 3-wire (NPN) F59W Diagnostic indication (2-color indicator) 5 V, 12 V IC circuit M9PW 3-wire (PNP) F5PW M9BW 24 V 2-wire 12 V Grommet J59W M9NA1 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V M9PA1 Water resistant (2-color indicator) M9BA1 2-wire 12 V F5BA1 F59F 4-wire (NPN) IC circuit IC circuit IC circuit 5 V, 12 V Diagnostic output (2-color indicator) A96 A93
Terminal conduit M9NW 3-wire (NPN) Relay PLC Yes G59W 5 V, 12 V Diagnostic indication (2-color indicator) IC circuit M9PW 3-wire (PNP) G5PW 24 V M9BW 2-wire 12 V K59W Grommet M9NA1 M9PA1 M9BA1 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Water resistant (2-color indicator) 12 V 2-wire G5BA G59F F59F 4-wire (NPN) 5 V, 12 V IC circuit IC circuit Diagnostic output (2-color indicator) A96 A93
(NPN) 5 V, 12 V M9NA** v v V v v 3-wire (PNP) M9PA** v v V v v Water resistant (2-color indication) 2-wire 12 V M9BA** v v V v v G5BA** V v v With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V F59F G59F V V v v IC circuit Magnetic field resistant (2-color indication) 2-wire (Non-polar) P3DWA V V v Yes 3-wire (NPN equivalent) 5 V A96 V V IC circuit 100 V A93
Lead wire length (m) Load voltage 5 (Z) Applicable load Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 1 (M) 3 (L) AC DC 12 V In-line A93 M9N M9B Reed auto switch 24 V 2-wire 100 V 12 V Relay, PLC Grommet Yes 3-wire (NPN) Solid state auto switch 24 V Relay, PLC Grommet Yes 12 V 2-wire Lead wire length symbols
(mm) D-A90V D-A96V D-A93V 22 Bore size D-M9V D-F9WV D-M9 D-F9W D-A90 D-A96 D-A93 (mm) 32 20 32 Mounting pattern q, w 35 Mounting pattern e 20 12 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries. Insert the auto switch into the switch groove.
Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
Applicable wafer size 200 mm 300 mm XM XY Non-cassette type DXSA Auto switch and connector XVD Symbol Auto switch Connector Nil A None Lead wire: 0.5 m (without connector) XGT XGT For 200 mm wafer For 300 mm wafer CYV With multiple connector Note 1) C Cassette type D-A93 (With 2 pcs. for opening and closing) (T3106 000: Made by AMP) With D-sub connector Note 2) F (CDE-9PF05: Made by HIROSE
Lead wire length symbols: Auto switches marked with are made-to-order specification. 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Auto switches other than those listed above are also available. Refer to page 11-8-9 for details.