SMC Corporation of America
Elite Part Number Search
Search Results "PF3W740-N04-DN-M-X109"

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90

Rated Flow Range: 10 to 1000 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: NPN; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: -, Option 2: -, Calibration Certificate: -

Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Option 1: N (w/o Lead Wire and M8 Connector)

Flow Rate Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: D (NPN; Analog 4 to 20 mA), Option 1: N (No Lead Wire)

Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: D (NPN; Analog 4 to 20 mA), Option 1: N (No Lead Wire)

Flow Rate Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: NPN; Analog 4 to 20 mA, Option 1: No Lead Wire, Unit Specifications: -, Option 2: -, Calibration Certificate: -

Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: NPN; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: -, Option 2: -, Calibration Certificate: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: EPDM Seal Material

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch.  Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility.  Designed to work with fluids up to 90ºC

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FB, IFW/PFW 1/2INCH NPT VERSION, 1.54323 lb

Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.