H2 A WH NN I MM H1 NE D LY ND NB 4-LD LH LT NF E 10 E JD N 10 JC N NA X Y X Y S+Stroke LX LZ LS+Stroke ZZ+Stroke (mm) Bore (mm) 20 25 32 40 Stroke range (mm) 200 to 700 200 to 700 200 to 1000 200 to 1000 I 26 31 38 47 F 16 16 19 21 A 18 22 22 24 E 14.5 18 18 20.5 D 10 12 12 16 GB 47.5 49.5 51.5 51.5 GA 53.5 56.5 55 56 Eff. thread length 15.5 19.5 19.5 21 JC 43 39 36 32 H1 5 6 6 8 LH 25 28
q Body size 20 30 40 50 60 Symbol Description w Pipe thread type Nil Metric thread (M5) Rc N Note 1) NPT F Note 2) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + e Port size a Mounting Nil Without mounting option B Note 3) With bracket + Option r Nil Polycarbonate bowl 2 Metal bowl 6 Nylon bowl 8 Metal bowl with level gauge C With bowl guard Note 6) Note 6) Note 6) Note 6) b Bowl 6C
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type]
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Port Size: 01 [R1/8 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type], Lead Wire: N (None)
Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 01 [R1/8 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 01 [R1/8 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type], Lead Wire: N (None)
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Port Size: 01 [R1/8 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 01 [R1/8 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type]
Positioning Mode: Minimum actuator travel distance of 1[m]. 28 - Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/LEYG25D LEY32/LEYG32 LEY32D/LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para. No Initial value Recommended value Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3.
Nm mm MHL2-10D M4X0.7 1.4 5 MHL2-10D M4X0.7 2.1 8 MHL2-16D M5X0.8 2.8 7 MHL2-16D M5X0.8 4.3 10 MHL2-20D M6X1 4.8 7 MHL2-20D M6X1 7.3 12 MHL2-25D M8X1.25 12 7 MHL2-25D M8X1.25 17.7 16 MHL2-32D M8X1.25 12 11 MHL2-32D M8X1.25 18 16 MHL2-40D M0X1.5 24 12 MHL2-40D M10X1.5 36 20 Nm MHL2-10D M4X0.7 2.1 MHL2-16D M5X0.8 4.3 MHL2-20D M6X1 7.3 MHL2-25D M8X1.25 17.7 6 - 1. 2. 2 <> AS1200-M5AS2200-01
// JXC93 Series 1. . 5 2. . 7 2.1. . 7 2.2 . 8 2.3 . 9 3. . 10 3.1 . 10 3.2 . 11 3.3 . 11 3.4 . 11 3.5 . 11 1 . 11 (2) . 12 (3) . 13 3.6 . 14 1 . 14 (2). 17 (3) . 19 3.7 JOG . 20 (1) . 20 2 . 21 (3) JOG . 22 3.8 . 23 (1) . 23 (2) . 23 3 . 24 (4) . 24 3.9 EtherNet/IP . 25 (1) . 25 (2) PLC . 25 (3) LED . 25 3.10 PLC . 25 4. . 26 4.1. . 26 4.2 EtherNet/IP . 27 4.3. . 28
Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
: 6 x 4 nylon tubing Name plate and caution plate for bowl in imperial units (PSI, F) Applicable model AL30 to 60 AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 Body size 10 20 30 40 50 60 Thread type Metric thread (M5) Rc NPT G Nil N F AL20 Port size Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 Note 2) M5 01
(Stacking base) Dimensions / Single unit (Base Mounted) 7 11 28 3 Specifications Poppet Valve construction Air, Inert gas Fluid Vacuum (1.33 x 102Pa) to max. operating press. (Refer to flow characteristics table below.)
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
Refer to "LECSC2-T Operation Manual (Simplified Edition)", section 5.7 for how to set the Point table. -28- Recommended Parameter Values [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Series Lead symbol H A B H A B T Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para. Initial value Recommended value No.