Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without built-in magnet, Auto Switches: Without auto switch, Lead Wire
Series VVXA31/32 Dimensions 8 1 Pilot port Rc Mounting hole Indication of valve type Type indication (Gasket) Blanking plate Mounting hole n-Rc , 8 1 4 1 (Pitch) (Pitch) Stations 2 3 4 5 6 7 8 9 10 Model Symbol L1 L2 L1 L2 96 84 126 108 132 120 172 154 168 156 218 200 204 192 264 246 240 228 310 292 276 264 356 338 312 300 402 384 348 336 448 430 384 372 494 476 VVXA31 VVXA32 Symbol Model
The value of the effective area S, like that of sonic conductance C, expresses the ease of flow. (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + t When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + t Conversion with sonic conductance C: S = 5.0 x C(5) Q : Air flow rate [dm3/min (ANR)], dm3
Install this product after discharging the drainage that has already accumulated in Mounting Example Compressor Aftercooler Air tank Main line filter Air dryer How to Order ADM200 Port size OUT IN Symbol 04 03 3 8 3 8 Construction/Dimensions 1 2 3 8 Voltage 100 VAC Hz 1 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC 12 VDC 2 3 4 5 6 7 Set screw Operating
Size Single vane Double vane Adjustment range of adjustment bolt (B) 90 145 150 1 25 Adjustment range of adjustment bolt (A) (S): 10 (D): 5 180 140 90 230 240 90 (S): 10 (D): 5 3 30 180 225 90 360 375 7 50 180 355 90 510 580 20 60 22.5 180 505 Allowable Load Positioning pin hole Do not permit the load and moment applied to the table to exceed the allowable values shown in the table below
Port sizes available are 1/8Rc(PT), and 1/4, 3/8 and 1/2 with Rc(PT), NPT or G(PF) thread types.Single sided connections series, Mass reduced by 20%, Max. flow 140 /min (ANR) and 240 /min (ANR), Integrated digital pressure switch for panel mounting, Built-in one-touch fittings REGULATOR, VACUUM. VACUUM REGULATOR. 385.50000 lb. 817.
Body Size: 20 [Max Flow 240 â„“/min (ANR)], Single Sided Connections: None, Fittings: L (Elbow), Connection Tubing O.D.: C10 (ø10mm), Bracket: B (With Bracket), Accessory: ZA (w/Digital Pressure Switch, NPN, 2 Outputs)
Accuracy: High-precision Type, Size: 63, Motor Type: S7 [AC Servo Motor (Absolute Encoder) 200W], Lead (mm): 10, Stroke (mm): 890, Motor Option: None, Cable Type: Robotic Cable, Flexible Cable, Cable Length: 10m, Driver Type: LECSS2-S*/T, S: 200 to 230 Power Supply Voltage; T: 200 to 240 Power Supply Voltage, I/O Connector: 1.5m
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Port sizes available are 1/8Rc(PT), and 1/4, 3/8 and 1/2 with Rc(PT), NPT or G(PF) thread types.Single sided connections series, Mass reduced by 20%, Max. flow 140 /min (ANR) and 240 /min (ANR), Integrated digital pressure switch for panel mounting, Built-in one-touch fittings REGULATOR, VACUUM. VACUUM REGULATOR. 239.00000 lb. 817.
Model IZN10E-Cm-m Input voltage*1 100 to 240 VAC, 50/60 Hz Output voltage 24 VDC Output current 1 A max Ambient temperature Operating 0 to 40C Stored 20 to 60C Ambient humidity Operating/Stored 10 to 90%RH Standards/Directive CE, cUL *1 For the AC cord type, note that the rated voltage of the AC cord included as an accessory is 125 V (See page 13). 11 Nozzle Type Ionizer IZN10E Series Accessories
0.3 m (99.9% filtered particle size) AFD20-A to AFD40-06-A 0.01 m (99.9% filtered particle size) Outlet side oil mist concentration AFM20-A to AFM40-06-A Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) 2 3 AFD20-A to AFD40-06-A Max. 0.1 mg/m3 (ANR) (Before saturated with oil 0.01 mg/m3 (ANR) or less 0.008 ppm) 2 3 Rated flow [L/min (ANR)] 1 AFM20-A to AFM40-06-A 200 450 1100 AFD20-A to AFD40-06-A 120 240
(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.