weight m (kg) Load weight m (kg) 30 30 MGF63 10 20 20 MGF63 5 10 10 MGF40 5 4 3 5 4 3 MGF40 MGF40 5 MGF40 2 2 3 5 2 1 1 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200 300 400 10 50 100 5 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) How to read the graph 1) When the load weight is 70kg, eccentric distance is 60mm, and the maximum speed is 150mm
Note 6) The flow rate unit is based on 0C and 101.3kPa. 2 For Air Digital Flow Switch Series PFA How to Order PFA5 Remote Type Sensor Unit 10 01 Wiring specification Flow rate range 3m lead wire with connector Without lead wire Nil N 1 to 10l/min 5 to 50l/min 10 to 100l/min 20 to 200l/min 50 to 500l/min Nil N F 10 50 11 21 51 Port size Thread type Size Applicable model Flow rate (l/min)
Digital Flow Switch Unit Specifications Detection type Heat type Measured flow range 50 to 500 L/min 5 to 100 L/min Minimum unit setting 5 L/min 1 L/min Accumulated pulse flow rate exchange value (Pulse width: 50 [ms]) 5 L/pulse 1 L/pulse Accumulated flow range 0 to 9 L 5% F.S. or less (15 to 35C: Based on 25C) Linearity 2% F.S. or less Repeatability 5% F.S. or less (15 to 35C: Based on 25C
20 15 10 2 pcs. 10 10 25 to 5 20 15 5 1 pc. 10 10 25 CXTl25 5 15 10 10 2 pcs. 10 15 20 CXTl 32 40 5 15 10 5 1 pc. 10 10 20 (mm) D-F7lW D-J79W D-F9BAL D-F7NT D-F79F Auto switch model D-A7l D-A8l D-A73C D-A80C D-A7lH D-A80H D-F7l D-J79 D-F7lV D-J79C Applicable model D-F7lWV D-A79W D-F7LF Number of mountings 2 pcs. 5 10 15 15 20 20 25 CXTl 32 40 1 pc. 5 5 10 15 15 20 25 3.8-10 Platform Cylinder
rated voltage 1 2 3 4 5 6 9 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Other (1) : Option Note 1) Except for large flow capacity style.
Vacuum pressure Suction flow rate 13-5-5 6 Series ZH Box Type (Built-in silencer): ZHB -S L One-touch connection Applicable tubing diameter B Model A 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 63 6 23 18 12.8 29 5 50 63 6 23 18 12.8 29 5 50 78 8 27.5 23 13.7 35 7 61 78 8 27.5 23 13.7 35 7 61 B C D E F G H ZH05BS-06-06 ZH05BL-06-06 ZH07BS
or less 20 190 35 62 50 10 or less 39 66 33 5 or less 30 190 39 68 43 10 or less 43 72 29 5 or less 50 190 49 83 33 10 or less 53 87 22 5 or less 70 190 54 95 30 10 or less 58 99 21 5 or less 100 190 61 108 27 10 or less 65 112 18 5 or less 200 190 81 139 21 10 or less 85 143 15 5 or less Operating range m: Value of the operating range Lm of a single auto switch converted to an axial rotation
model 30 13.1 7.4 Up to 50% shorter 40 19.2 12.2 50 (Port size 3/4) 34.8 22.6 AV2000-A New New Fill time 50 (Port size 1") 41.3 24.4 Current model For 1(P) R 2(A) Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300 250 200 New New AV2000-A 150 100 50 0 0 1 2 3 4 5 6 Number of needle
Actuation Plug Plug (A) 4 (B) (2) Number of solenoids (A) (4) (B) 2 Single 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) Plug Plug (A) (4) (B) 2 (A) 4 (B) (2) Manual Override Operation Double Warning 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) Light/Surge Voltage Suppressor Handle carefully, as connected equipment can be actuated through manual override operation.
Port Body ported type M3 0.5 50 54 3 position 59(33) 73(47) 61(35) 77(51) 2 position 5 Port Base mounted type (With sub-plate) 1.8 (0.1) Body ported type M5 0.8 76(50) 80(54) 3 position 33 47 35 51 2 position 4 Port Base mounted type For manifold use only Note1) 1.2 (0.067) _ ( ) 50 54 3 position Note1) In case of M5 and mounted on manifold base.
D 5 D 23 Q VO307 CE-compliant Coil rated voltage CE-compliant Coil rated voltage CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override
50 LECSB2-T8 to to LECSC2-T8 T8 400 40 LECSN2-T81200 1200 LECSS2-T8 *Refet to Applicable Stroke Table.
Solenoid valve rated voltage 5 12 VDC 24 VDC 6 V S R 1 Slotted locking type Non-locking push type Manual override 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 110 VAC 50/60 Hz 3 Nil Number of stations w-2 Individual specifications (Symbol , , , , ) Indicate X for required station.
(OUT05)OFF 11INPOFF ... 12BUSY ON 0mm 50mm 60mm 100mm 5 13DRIVEOFF 14No.2 ON (OUT1ON) 15INPON 16BUSYOFF 10mm 57 - 13.2 100mm/s 100mm (No.1 ) 100mm ,10mm/s 50% 5mm (INPON )50mm/s 50mm (No.2 ) No. 1 2 2 2 mm/s mm mm/s mm/s mm mm mm mm/s 0 1 ABS 100 100.00 1000 1000 50 40 10 100 0 0 5 2 ABS 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () 1No.1(IN0ON) / 2DRIVEON (2)(5)(10)(13) No.1
SV B00 SOL.b SOL.a 3(EB) 5(EA) 1(P) 4(A) 2(B) N.C. valve N.O. valve SOL.b SOL.a 1 2 SV C00 3(EB) 5(EA) 1(P) External pilot specification is not available for 4 position dual 3 port valves.
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
Movement Speed Position Acceleration Deceleration Area 1 Area 2 In pos force Force speed force 2 2 mode mm/s mm mm/s mm/s mm mm mm Value mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () (1)No.
40 40 50 P1 = 1 MPa P1 = 0.8 MPa P1 = 0.6 MPa 30 30 Example 2 20 20 P1 = 0.5 MPa P1 = 0.4 MPa Example 1 10 10 P1 = 0.3 MPa P1 = 0.2 MPa 4 5 5 4 P1 = 0.1 MPa 3 3 2 2 1 1 0.001 0.01 0.1 0.002 0.003 0.02 0.03 0.04 0.004 Pressure differential P [MPa] Graph (2) Flow rate characteristics Example 1) Obtain the pressure difference when water [15 L/min] runs through the solenoid valve with a Kv =
Displayed values of the pressure sensors can be adjusted to within 5%. Applicable pressure sensor PSE531 PSE541 PSE561 PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) pressure range 5%R.D.