How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC
Class B or equivalent 50 Hz 5.6 Apparent Inrush 60 Hz 5.0 power 50 Hz 3.4 (VA) Holding 60 Hz 2.3 Power consumption (W) 1.8 Surge voltage suppressor and indicator light Available as option Note 1) Pilot pressure range should be 0.1 to 1 MPa (14.5 to 145 psi).
, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting B L F D Basic type Axial foot type Front flange type Double clevis type CJ5 L 16 S R 60 Without Auto Switch CDJ5 L 16 S R 60 H7BAL With Auto Switch With auto switch (built-in magnet) Number of auto switches 2 pcs. 1 pc.
02 VX2 602 10 15 5 3 5 10 15 20 25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).
, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 (Both sides) 1300 25 12-CY3B25 Non-lube 32 12-CY3B32 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B40 40 Note 1) Stroke exceeding the standard stroke but below the maximum possible stroke is available for special order upon request.
After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.
to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)Three phase 170 to 253 VACSingle phase 170 to 253 VAC1.5Single phase 200 to 230 VAC (50/60 Hz)Single phase 170 to 253 VAC0.210 inputs6 outputs1 M (when differential receiver), 200 k (when open collector)0 to ?
Flow rate Max. rated flow rated flow 5 3-Color Display Electromagnetic Digital Flow Switch LFE Series Flow Rate Characteristics (Pressure Loss) LFE1 LFE2 LFE3 0.02 0.02 0.02 Pressure loss [MPa] Pressure loss [MPa] Pressure loss [MPa] 0.015 0.015 0.015 0.01 0.01 0.01 0.005 0.005 0.005 0 0 0 0 5 10 15 20 0 20 40 60 80 100 0 50 100 150 200 Flow value [L/min] Flow value [L/min] Flow value [L/
S3 32 200 S3 200 to 230VAC LECSA2 A2 200 to 230VAC LECSA2 A2 Both side D Both side D 40 400 S4 40 400 S4 100 to 120VAC 100 to 120VAC LECSB1 LECSB1 B1 B1 25 100 S6 25 100 S6 Motor option 32 200 S7 AC servo motor (Absolute encoder 32 200 S7 AC servo motor (Absolute encoder LECSB2 LECSB2 200 to 230VAC B2 200 to 230VAC B2 B1,B2 B1,B2 Without lock Nil Without lock Nil 400 400 40 40 S8 S8 Cable
Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
25 32 M16 x 1.5 26 M5 x 0.8 16 25 16 76 60 25 32 M20 x 1.5 31 M5 x 0.8 16 F J E 31.5 20 90 70 30 40 M24 x 1.5 36 M5 x 0.8 20 dH10 B series rod 40 31.5 145 115 45 60 M30 x 1.5 50 M6 x 1.0 30 40 31.5 145 115 45 60 M39 x 1.5 61 M6 x 1.0 30 H0.1 0.4 D 50 40 185 145 57 79 M48 x 1.5 76 M8 x 1.25 40 25 16 76 60 25 32 M16 x 1.5 26 M5 x 0.8 16 C 31.5 20 90 70 30 40 M20 x 1.5 31 M5 x 0.8 20 K B 40
How to Order AR 30 BE F 1N 03 Optional specifications Regulator Symbol 1 N R Y Z Description 0.02 to 0.2MPa setting Non-relieving Flow direction: Right to left Upward handle Name plate and pressure gauge in imperial units (PSI, F) Applicable model AR10 to 60 AR10 to 60 AR10 to 60 AR10 to 60 AR10 to 60 Note 2) Body size 10 20 25 30 40 50 60 Thread type AR20 Note 3) When more than one specification
to left AF30 to 60 F Note 2) R Z Note 6) AF20 to 60 Note 1) Drain guide is NPT1/4 (applicable to AC30 to 60) Note 2) Drain guide is G1/4 (applicable to AF30 to 60).
W Mounting orientation: Horizontal Operating pressure: 0.5 MPa Allowable Lateral Load at Rod End Standard Type: MQQTB Anti-lateral Load Type: MQQLB/Built-in Ball Bushing Type 60 5 50 4 Maximum allowable lateral load W (N) Maximum allowable lateral load W (N) 28 40 3 28 25 30 25 2 20 20 20 16 16 1 10 10 10 30 60 75 100 30 60 75 100 Stroke (mm) Stroke (mm) Note 1) The allowable lateral load
W Mounting orientation: Horizontal Operating pressure: 0.5 MPa Allowable Lateral Load at Rod End Standard Type: MQQTB Anti-lateral Load Type: MQQLB/Built-in Ball Bushing Type 60 5 50 4 Maximum allowable lateral load W (N) Maximum allowable lateral load W (N) 28 40 3 28 25 30 25 2 20 20 20 16 16 1 10 10 10 30 60 75 100 30 60 75 100 Stroke (mm) Stroke (mm) Note 1) The allowable lateral load
Adsorbent for low dew point Symbol Port size Symbol Size Applicable standard size Power supply voltage Thread type 20 30 40 60 Symbol Description 02 04 06 1 4 1 2 3 4 Symbol Nil Type Rc Single phase 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer ID
ON/OFF LED PLC ST(0) () ON/OFF ST / (60 ) -37No.EX-OMN0029CN-D EX600No. H.T. () LED PLC 0 1 5 AXA / () / / H.T. () LED PLC 6 AYA () / / (60 ) -38No.EX-OMN0029CN-D EX600No. H.T. () LED PLC 0 1 7 AMB / () / / / / H.T. (SI ) ON/OFF LED PLC ON/OFF 8 ST(M) () ST(M) SI 9 ST(M) OFF PWR () DC24 V10 10 PWR(V) () DC24 V+10/-5 (60 ) -39No.EX-OMN0029CN-D No.
PP-700-5 PP-700-15 PP-700-30 PP-700-60 PP-700-100 1 1 1 3 5 5 15 30 60 100 30 60 60 120 120 0.2 0.3 0.3 0.5 0.7 0.4 0.6 1.0 2.0 3.5 PPMOUNTING STYLE BARBED FITTING (FM & PM ONLY) VALVE FUNCTION RANGE (PSI) FM = FLUSH MOUNT PM = PANEL MOUNT PT = PIPE THREAD MM = MANIFOLD B80 = NYLON 1/16" I.D. TUBE B85 = NYLON 1/8" I.D.