VV5Q12 06 N7 PSO D 1. How to Order Indicate an option symbol, K, for the manifold no. and be sure to specify the mounting position and number of stations of the single and double wiring by means of the manifold specification form.
Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !
L8 3 2 B4 1 B6 Stations B8 D side LM Note 1) For CM, indicate in the specification table. Note 2) Inch sizes use the following symbols. N3: 5/32 N7: 1/4 N9: 5/16 NM: Mixed Top ported elbows are LN and bottom ported elbows are BN. Note) Stations are counted starting from station 1 on the D side. 2.
) N7 N9 C6, C8, Directional Control Valves Air Grippers Modular F.
SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 8 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting)
Enclosure: W (IP67), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 8 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: 63 [6 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: N (-COM), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: None, Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: +COM, Stations: 8 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting)
SI Unit: 0 (w/o SI Unit), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
SI Unit: Q (DeviceNet Omron CompoBus/D), Stations: 8 Stations, PE Port Location: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
SI Unit: R1 (Omron CompoBus/S 16 Points), Stations: 8 Stations, PE Port Location: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: D-sub connector compatible tie-rod base manifold, Number of Inputs/Outputs: -, Connector: Upward Connector, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø5/16" single-action pipe fitting (P-, E-Port), Specification