SMC Corporation of America
Elite Part Number Search
Search Results "SY3120-SLOZ-N7-F1"

F1 Holding point L (mm) Holding point L (mm) F1 2.3-19 3 Finger Air Gripper Series MHR3/MDHR3 Construction MHR3 !

systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK system (16 point output) Sanks: S-LINK system (8 point output) Fuji Electric: T-LINK mini system DeviceNet and OMRON Compo Bus/D OMRON: Compo Bus/S (16 points) OMRON: Compo Bus/S (8 points) JEMANET Mitsubishi: CC link system T O A B Kit (Terminal block box kit) BB C D F1

No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO

When A port pressure is lower than P1 port pressure, F1 becomes larger than F2, and the pressure regulating piston moves downwards,opening the lower poppet valves.Thus air is supplied from P port to A port.(DRW(3)) When A port pressure rises enough to restore the balance, the regulator valve returns again to the DRW(2) condition.

systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK system (16 point output) Sanks: S-LINK system (8 point output) Fuji Electric: T-LINK mini system DeviceNet and OMRON Compo Bus/D OMRON: Compo Bus/S (16 points) OMRON: Compo Bus/S (8 points) JEMANET Mitsubishi: CC link system T O A B Kit (Terminal block box kit) BB C D F1

Series: 10-SY3000, Actuation: 2 Position, Single, Coil Specification: None, Voltage: 24 VDC, Electrical Entry: M8 Connector, w/o Connector Cable, Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-Locking Push Type, A, B Port Size: One-touch Fitting for ø5/32", Thread: Rc, Bracket: w/Foot Bracket, 2 Position Single Only

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: M, Port Size: M5, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.15

Series: 3 (10-SY3000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: WO (M8 Connector, w/o Connector Cable), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-Locking Push Type, A, B Port Size: N3 (One-touch Fitting for ø5/32"), Thread: Rc, Bracket: F1 (w/Foot Bracket, 2 Position Single Only)

Series: 3 (10-SY3000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: L [L Plug Connector, w/Lead Wire, (300mm)], Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: M5 (M5 x 0.8), Thread: Rc, Bracket: F1 (w/Foot Bracket, 2 Position Single Only)

Series: 10-SY3000, Actuation: 2 Position, Single, Coil Specification: None, Voltage: 24 VDC, Electrical Entry: L [L Plug Connector, w/Lead Wire, (300mm)], Light/Surge Voltage Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-Locking Push Type, A, B Port Size: M5 x 0.8, Thread: Rc, Bracket: w/Foot Bracket, 2 Position Single Only

Compatible Fluid: Air, Operating Environment: Standard / No Oil, Type: Air Operating Type, Switching Type: [Others] 2-position exhaust, Connection Type: Tube Connection, Plumbing Thread Nominal: -, Tube Diameter: φ6.35, Operating Temperature Range(°C): -10~60, Driving Type: Pilot Type, Bracket: With foot bracket, Valve Type: Body ported type, Pilot number: Single

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

Allowable Driving Force Table (Fn) (n=1,2,3) F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 1466 for the maximum load weight when loaded directly on the body and connection bracket.) F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for the (Fn) of data K A .

(KB) KA 2 x 2 x OB counterbore depth RB M Z X B + Stroke L EB A + Stroke EA E Axial piping Bore size (mm) F1 32 40 50 63 30 34.5 43.5 51 Bore size (mm) Stroke range (mm) A B E EA EB F HA HB J KA KB L M N OA 32 40 50 63 5 +0.2 0 5 +0.2 0 6 +0.2 0 6 +0.2 0 28 0.2 33 Note 1) 40 Note 1) 45 43 34.4 6.5 M5 x 0.8 22.5 19.8 7 34 5.4 M6 x 1 5 to 100 33 0.2 39.5 52 50 41.4 6.5 M5 x 0.8 26 23.3 7 40

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load (kg) Note: 1 Nm = 0.7375 ftlb 1 kg = 2.2046 lb 1 in = 25.4 mm W1 W W m Moment (Nm) M = F x L M = F x L M = F x L F3 F2 F1 L2 L1 L3 1. Maximum allowable load (1), static moment (2), and dynamic moment (at the time of impact with stopper) (3) must be examined for the selection calculations.

Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum load weight (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).