SMC Corporation of America
Elite Part Number Search
Search Results "VV5K3-41-02-M5"

M5 X 0.8 (Finger opening port) 22.5 2.3 2.4-13 Series MHK2 Dimensions MHK2-20l /Standard model 18.6 20 2-M5 X 0.8 thread depth 8 (Mounting thread) 4H9 depth 4 +0.030 0 21H9 depth 1.5 +0.052 0 2-M5 X 0.8 thread depth 10 (Mounting thread) 4-M5 X 0.8 thread depth 10 (Mounting thread) Bottom hole 4.3 through (Mounting hole) 0 -0.1 8 Open 26 +1.2 0 5 16 0.02 13 . 5 42 30 60 58 32 0 -0.2 29 Closed

M5 X 0.8 (Finger opening port) 22.5 2.3 19 Series MHK2 Wedge Cam Operation Gripper Dimensions MHK2-20 /Standard model Scale: 37% (mm) 18.6 20 2-M5 X 0.8 thread 8 deep 4H9 4 deep +0.030 0 21H9 1.5 deep +0.052 0 2-M5 X .8 thread 10 deep 4-M5 X 0.8 thread 10 deep Bottom hole dia.4.3 through-hole 0 -0.1 8 Open 26 +1.2 0 5 13.5 16 0.02 60 58 32 42 30 0 -0.2 Closed 16 29 4H9 4 deep +0.030 0 21

Mode button 1s Set button 1s or Mode button 1s Set button 1s Fig. 41-1 No.IP8S-OM09 57 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 41-2 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 41-3 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. When changing the detecting position, carry out in the state of 3. Auto Switch Mounting Bracket Part No.

M5 M6 M6 Bracket mounting a b f g h i Port size P Model j 37 41 46 48 a1 Note) d e 2.3 2.3 2.3 2.3 3 A 4 B 5 C 6 D VXZ2 VXZ2 VXZ2 VXZ2 1/4, 3/8 1/2 3/4 1 56 56 70.5 70.5 52 60 68 73 75 75 92 92 30 34.5 39 41 6.5 6.5 6.5 6.5 10.5 10.5 10.5 10.5 31 35 43 45 13.5 Electrical entry Conduit terminal Conduit Faston Port size P Model Q R Q R Q R S T 71 71 73.5 73.5 3 A 4 B 5 C 6 D VXZ2 VXZ2 VXZ2

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.

: Nil (Top entry) Rod operating range Note 1) 2 x M5 x 0.8 thread depth 9 [1] 1 20 Motor cable length 300 2 x 5 Origin Note 2) Stroke end [Origin] Note 3) 20 [Stroke end] M5 x 0.8 thread depth 9 Manual override screw 21 42 28 12 Note 5) 28 Motor cable mounting direction: L (Entry on the left side) A 7 12 Stroke L2 L1 Mounting surface 18 5.5 12 Note 5) Motor cable mounting direction: U (Bottom

NH NC DTT UU TT UU Auto switch magnet holder M5 x 0.8 (Port) -X GA GA 2-M5 x 0.8 (Hexagon socket head plug) 2-M5 x 0.8 (Hexagon socket head plug) Cushion needle G G 20GB M5 x 0.8 (Hexagon socket head plug) N A M5 x 0.8 (Port) Data Z + Stroke M5 x 0.8 (WW) (WW) (Hexagon socket head plug) 2 x 2-J depth K M5 x 0.8 (Hexagon socket head plug) XX XX M5 x 0.8 (Port) VV VV 2-M5 x 0.8 (Hexagon socket

x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 ( ): Denotes the values of D-A44C Dimensions (mm) D-A3C D-A44C 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 G 1/2 4 x Z 4 x Z (Applicable cable O.D. 6.8 to 9.6) (Applicable cable O.D. 6.8 to 11.5) Hexagon socket head cap bolt Hexagon socket head cap bolt Indicator

MHF2-16D1 Scale: 50% 4H9 +0.030 0 depth 3 60 4H9 +0.030 0 depth 3 2-M5 x 0.8 thread depth 12 Mounting thread 6 79.5 5 M5 x 0.8 2-M5 x 0.8 thread depth 5.5 50 94 Mounting thread Finger closing port 26 74 10.6 E 20 20 24 33 E 0 -0.1 1.2 2-4.3 through (mounting hole) 27 29 1.2 29 M5 x 0.8 2-7.5 +0.1 0 Close: 0 Finger opening port E-E Open: 321 58 4-M5 x 0.8 thread depth 5.5 8-M4 x 0.7 thread

20 122 464 Low Profile Air Gripper Series MHF2 Dimensions MHF2-20D 38 5H9+0.030 0 depth 4 5H9 +0.030 0 depth 4 2 x M6 x 1 thread depth 15 6 71 6 (Mounting thread) 62 86 2 x M6 x 1 thread depth 6 33 56 M5 x 0.8 Finger closing port (Mounting thread) E 13 25 25 30 41 E MHZ 2 x 5.2 through (Mounting hole) 0 0.1 32 31 31 MHF M5 x 0.8 2 x 10 1.2 1.2 Finger opening port MHL E-E Close: 0 +0.1 0

Setting of switch operation 1_P/1_N (page 37) (Selection of display colour) Setting of Add dEC1 dEC2 (page 41) 3. Input of set values Setting of Setting of P1L/n1L Setting of P_1/n_1 P1H/n1H P1/n1 H_1 WH1 (page 40) (page 37) (page 39) 4. Delay time Setting of dtH1(ON) dtL1(OFF) (page 38) 5. Selection of display colour rED/Grn/1SoG/1Sor/2SoG/2Sor (page 41) 6.

00 Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 Belgium (32) 3-355 14 64 Netherlands (31) 20-531 8 Germany (49) 6103 4020 Sweden (46) 8-603 12 00 Protection ground terminal (420) 5-414 24611 Norway (47) 67 12 90 20 Austria (43) 2262-62 280 Italy (39) 02-927 11 terminal on the end of motor, using a metal P-clip on to the Country Telephone

6 MHS 62 86 MHC 33 Finger closing port M5 x 0.8 2-M6 x 1 thread depth 6 56 MHT Mounting thread E 13 MHY 25 30 41 25 MHW MRHQ 2-5.2 through (Mounting hole) 0 -0.1 32 E Misc.

MHZ MHF MHL 2-M5 x 0.8 thread depth 12 MHR Mounting thread 6 79.5 5 MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHS M5 x 0.8 2-M5 x 0.8 thread depth 5.5 50 94 Finger closing port Mounting thread MHC 26 74 10.6 MHT E MHY 20 20 24 33 MHW E MRHQ 2-4.3 through

LEHZ40 LEHF10 LEHF20 LEHF32 LEHF40 M3 x 0.5 M4 x 0.7 0.9 1.4 M3 x 0.5 M5 x 0.8 0.9 3.0 M4 x 0.7 M6 x 1 1.4 5.0 M5 x 0.8 M6 x 1 3.0 5.0 M5 x 0.8 3.0 M6 x 1 5.0 When using the thread on the back of the body When using the thread on the back of the body Max. screw-in depth L [mm] Max. tightening torque [Nm] 10 Max. tightening torque [Nm] 6 Max. screw-in depth L [mm] Model Model Bolt Bolt LEHZ

SWITZERLAND (41) 052 396 31 31 Dorfstrasse 7, CH-8484, Weisslingen, Switzerland Diagnostic Step 3 Connection to PLC UNITED KINGDOM (44) 0845 121 5122 Note) Refer to the operation manual of the PLC manufacturer for connection to PLC and Configurator.

Remote connection system status Specification Str Frunzei 29, Sector 2, Bucharest, Romania W-MS SLOVAKIA (421) 41 321321 1 Remote (EX600-WSV#) can be used regardless of the communication specification of the base. (3) Set the "base" system.

Poloneza 89, 02-826 Warszawa, Poland PORTUGAL (351) 21 472 45 00 Alameda dos Moinhos, 9G, 2720-381 Alfragide Portugal ROMANIA (40) 213205111 Str Frunzei 29, Sector 2, Bucharest, Romania SLOVAKIA (421) 41 321321 1 Fantransk 1223, 01301 Teplika nad Vhom, Slovakia SLOVENIA (386) 7388 5412 Mirnska cesta 7, SLO-8210 Trebnje, Slovenia SPAIN (34) 945 184 100 Zuazobidea 14, 01015 Vitoria, Spain SWEDEN

Figure 5-41 Serial Communication Setting Screen 2 [Tips] The setting has not taken effect while the box is flashing. 2. Touch the [Enter] key. The MESSAGE screen is displayed. Figure 5-42 Serial Communication Setting Screen 2 3. Touch the [YES] key. The setting takes effect.