IDX-OM-U010-H PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFC60-23-C,L,R,T,V IDFC70-23-C,L,R,T,V IDFC80-23-C,L,R,T,V IDFC90-23-C,L,R,T,V This manual is intended to explain the installation and operation of the product.
0 @1 r ye t !4 !7 !3 wu !8 @0 @2 @3 !6 q !5 !9 i *1 *1 C95K32 A A-A A !2 !
11 T T 11.1 11.2 AC240V / DC24V 5A() / 2A() DC20V 3mA IDFC60/70/80/90 Series 11-1 IDX-OM-W095 T 11.3 AC230V ON A(4-5) B6-7 A4-5A B6-7B 3 5 /() OFF 3 OFF6.2 IDFC60/70/80/90 Series 11-2 IDX-OM-W095 T 11.4 M3.5 1.01.3Nm M4.0 1.42.0Nm 6 5 4 1 2 3 PE N L 7 L,N PE B A IDFC60-23-TIDFC70-23-T IDFC80-23-TIDFC90-23-T M3.5 8.5mm M4.0 9.5mm [3.2.5 ] IDFC60/70/80/90 Series
Magnet With auto switch only 9 Magnet plate Stainless steel With auto switch only 10 Scraper 11 Rod seal 12 Piston seal NBR 13 Tube gasket 14 Piston gasket 269 CHKD Series Dimensions Basic type/CHKDB 2 x Rc P F with effective thread depth G F with effective thread depth G Q Q Width across flats f c R D R a b g e H E E h + Stroke C B + Stroke 4 x K through 8 x L counter bore 4 x K through
rod side With cushion on rod side Basic Foot Front flange Rear flange Single clevis Double clevis Center trunnion B L F G C D T Cushion With both sides cushion (Air-hydyo style: No cushion) If specifying more than one symbol, please indicate them in alphabetical order.
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: Panel Mount Rear or Bottom Ported, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: Panel Mount Rear or Bottom Ported, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: Panel Mount Rear or Bottom Ported, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: Panel Mount + Front Protection Cover, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 1 Output, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: Panel Mount + Front Protection Cover, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: Panel Mount Rear or Bottom Ported, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: Panel Mount Rear or Bottom Ported, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: Panel Mount Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: Panel Mount + Front Protection Cover, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specifications: NPN, NPN, Option 1: No Lead Wire, Unit Specifications: Unit Selection Function, Option 2: With Panel Mount Adapter, Calibration Certificate: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: Calibration Certificate, X Options: -