Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F2 (G1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Input/Output: A1 (IN1: Common for NPN and PNP / INA: Analogue 1 to 5 V / OUT1: NPN / OUTA: Analogue 1 to 5 V), Power Supply Cable: C (w/Power Supply Cable, 3m), Bracket: S (Bracket)
Input/Output: A3 (IN1: Common for NPN and PNP / INA: Analogue 1 to 5 V / OUT1: PNP / OUTA: Analogue 1 to 5 V), Power Supply Cable: C (w/Power Supply Cable, 3m), Bracket: S (Bracket), Display: M (With Display)
Input/Output: A1 (IN1: Common for NPN and PNP / INA: Analogue 1 to 5 V / OUT1: NPN / OUTA: Analogue 1 to 5 V), Power Supply Cable: C (w/Power Supply Cable, 3m), Bracket: S (Bracket), Display: M (With Display)
Input/Output: A3 (IN1: Common for NPN and PNP / INA: Analogue 1 to 5 V / OUT1: PNP / OUTA: Analogue 1 to 5 V), Power Supply Cable: C (w/Power Supply Cable, 3m), Bracket: S (Bracket)
1% F.S. or less (15 to 35C, based on 25C)60 mA or less45 gMaximum load current: 80 mAInternal voltage drop: 1 V or less (with load current of 80 mA) NPN open collector (PF2W300, PF2W330) Maximum applied voltage: 30 V2 outputsMaximum load current: 80 mAPNP open collector (PF2W301, PF2W331) Internal voltage drop: 1.5 V or less (with load current of 80 mA)2 outputsNPN or PNP open collector (
In the SigmaWin+ main window, click Setup(S), point to Set Absolute Encoder(A) and click Reset Absolute Encoder(A). The absolute encoder can only be set up while the servo is off.
The product has a fan(s) and could cause serious danger to operators. 7-2 Specifications Cool outlet air (10oC) can be supplied.
System error Displayed if an internal data error has occurred. , The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer.
1% F.S. or less (15 to 35C, based on 25C)60 mA or less45 gMaximum load current: 80 mAInternal voltage drop: 1 V or less (with load current of 80 mA) NPN open collector (PF2W300, PF2W330) Maximum applied voltage: 30 V2 outputsMaximum load current: 80 mAPNP open collector (PF2W301, PF2W331) Internal voltage drop: 1.5 V or less (with load current of 80 mA)2 outputsNPN or PNP
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Switch output Current: Max. 100 mA Internal voltage drop: 1 V or less Switching between N.O. and N.C. modes is possible.
1% F.S. or less (15 to 35C, based on 25C)60 mA or less45 gMaximum load current: 80 mAInternal voltage drop: 1 V or less (with load current of 80 mA) NPN open collector (PF2W300, PF2W330) Maximum applied voltage: 30 V2 outputsMaximum load current: 80 mAPNP open collector (PF2W301, PF2W331) Internal voltage drop: 1.5 V or less (with load current of 80 mA)2 outputsNPN or PNP
1% F.S. or less (15 to 35C, based on 25C)60 mA or less45 gMaximum load current: 80 mAInternal voltage drop: 1 V or less (with load current of 80 mA) NPN open collector (PF2W300, PF2W330) Maximum applied voltage: 30 V2 outputsMaximum load current: 80 mAPNP open collector (PF2W301, PF2W331) Internal voltage drop: 1.5 V or less (with load current of 80 mA)2 outputsNPN or PNP