SMC Corporation of America
Elite Part Number Search
Search Results "ISE77G-02-L2-MS"

Connection Type: Others, Connection screw: M, Shape Type: Plug, Material: [Stainless Steel] 316 Stainless Steel, Gasket Material: PVC, Made to Order Specifications: N/A

Connection Type: Screw⇔Screw Connection, Connection screw: M, Thread-to-Thread Connection Shape: Universal elbow, Material: [Stainless Steel] 316 Stainless Steel, Gasket Material: PVC, Made to Order Specifications: N/A

Connection Type: Screw⇔Screw Branch Connection, Connection screw: M, Thread-to-Thread Multipoint Shape: [Universal Tees] Universal Tee, Material: [Stainless Steel] 316 Stainless Steel, Gasket Material: PVC, Made to Order Specifications: N/A

Connection Type: Screw⇔Screw Connection, Connection screw: M, Thread-to-Thread Connection Shape: [Male Straight] Nipple, Material: [Stainless Steel] 316 Stainless Steel, Gasket Material: PVC, Made to Order Specifications: N/A

Connection Type: Screw⇔Screw Connection, Connection screw: M, Thread-to-Thread Connection Shape: [Male Straight] Universal Nipple, Material: [Stainless Steel] 316 Stainless Steel, Gasket Material: PVC, Made to Order Specifications: N/A

Value range: 10 10, in 1 ms increments Unit: ms F_WD_Time 150 A CRC signature, which is calculated automatically via all F-Parameters and ensures error-free transmission of the F-Parameters.

Chattering-proof func. working: 20 ms, 160 ms, 640 ms, 1280 ms selected Repeatability 0.1%F.S. Voltage output 2 Output voltage: 1 to 5 V (within rated pressure range), Output impedance: approx.1 k Linearity: 0.2%F.S. (Without sensor), Response time: 150 ms or less Analogue output Accuracy 0.6%F.S. 1.0%F.S. 1.5%F.S.

(Page 83) WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 1026 0x0402 0 R/W U16 100 Y Setting of OUT2 delay time at ON 10 ms increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 to 0x1770 (0 to 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 10 ms increment 0: 0.5 sec 1: 1.0 sec 2: 2.0

) 1 L/pulse 070 () L/minL 3F.S. 3F.S. 2F.S. 2 5%F.S.(25 ) 3 3 9 L 4 1L NPN PNP 80 mA DC28 V NPN1 V (80 mA ) PNP1.5 V (80 mA ) 25 0.5 s/1 s/2 s 6 0.5 s/1 s/2 s 15 V 1 k 420 mA DC12 V 300 DC24 V 600 0.4 V ()30 ms 2 4 7 /6 11 ) 5 / 12 DC1224 V10 50 mA -68No.PF-OMM0004-D PF3W711 PF3W721 0.4 V ()30 ms 2 4 7 /6 11 ) 5 / 12 DC1224 V10 50 mA IP65 050 () 3585R.H

(Page 85) WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 1026 0x0402 0 R/W U16 100 Y Setting of OUT2 delay time at ON 10 ms increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 to 0x1770 (0 to 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 10 ms increment 0: 0.5 sec 1: 1.0 sec 2: 2.0

D-MS-A Mounting screw (M2.5 x 4 L, Steel (Black zinc chromate)) 1 pc. D-MS-AP Mounting screws (M2.5 x 4 L, Steel (Black zinc chromate)) 10 pcs. D-MS-B Mounting screw (M2.5 x 4 L, SUS) 1 pc. D-MS-BP Mounting screws (M2.5 x 4 L, SUS) 10 pcs. ISA-2-1 DIN rail (Width 35 mm x Length 105 mm) 1 pc. ISA-2-2 DIN rail (Width 35 mm x Length 140 mm) 1 pc.

Influenceof magnetic force 59 - Make sure to have intervals of 15 ms or longer (30 ms is recommended) between input signals and maintain the state of the signal for the same period because delay in PLC processing and electric actuator control part scan can occur.

Caution Make sure to have intervals of 15 ms or longer (30 ms is recommended) between input signals and maintain the state of the signal for the same period of time. 70 - Output side *When green is the I/O cable (JX-CI*-E-*-S) Wire Signal Terminal name Description color No.

Leave an interval of 15 ms minimum (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 8.5 Methods of interrupting operation There are two methods of interrupting operation and stopping the electric actuator during positioning operation

(recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur.

Keep the input signal combination for 15 ms (30 ms if possible) or longer. "9.1 Positioning operation" The electric actuator goes out the stroke limit specified by the basic parameters, "Stroke (+)" and "Stroke (-)" if it performs the requested operation.

The switch output will start within 10 ms of the auto-shift input signal. If the measured pressure exceeds the set pressure range during auto-shift input signal, the corrected value will not be stored and [o.r] is displayed for approximately 1 second.

(20,100,500,1000,2000 ms ) 0.2F.S. 1 digit 0 1 () 15 V2.5F.S. 0.65 V2.5F.S. 1F.S. 2 1 k () 420 mA2.5F.S. 2.420 mA2.5F.S. 1F.S. 3 12 V 300 24 V 600 50 ()Low 0.4 V 5 ms 3 1/2 7 LCD 2 (/) 2 F.S.1 digit(253 ) ON OUT1OUT2 IP65 -550 -1060 () 3585RH() AC1000 V 1 50 M (DC500 V ) 2F.S. (25 ) 5 3.52 m 0.15 mm 2(AWG26) 0.95 mm CEUL/CSARoHS 1 2 3 -60No.PS-OMM0006CN-E 01 N01