TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 12-CY3B6 12-CY3B10 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 12-CY3B50 12-CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2
Switch Pressure range 0.1 MPa 0 2 MPa 10 MPa 1 MPa 5 MPa ISE70 For 1 MPa (For air and general fluids) 0 0.105 MPa 1 MPa 1.05 MPa ISE70G 0 0.105 MPa 1.6 MPa For 1.6 MPa (For air) ISE71 1.68 MPa 0 0.105 MPa 2 MPa For 2 MPa (For general fluids) ISE75G 2.1 MPa 0 0.25 MPa 5 MPa For 5 MPa (For general fluids) ISE76G 5.25 MPa 0 0.50 MPa 10 MPa For 10 MPa (For general fluids) ISE77G 10.5 MPa Rated
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
Flow Rate and Effective Area Flow Direction Symbol on Body AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 1.5 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 2 6 8 1/4" 5/16" 460 7 6 10 8 10, 12 6 JIS symbol Inch size Tube O.D. 5/16" 5/32" 1/4" 1/4" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 660 10 290 4.5 390 6 920 14 920 14 1390 21 20 0.3 130 2 230 3.5 Controlled flow (Free flow) Effective
M12 x 1.75 27 14 34 35 34 100 125 15 100 250 16 112 170 M27 x 2 38 6.5 140 140 112 35.5 80 35 27 19 M14 x 2 27 16 34 35 34 100 160 17 110 279 18 140 197 M33 x 2 42 9 174 174 140 45 100 38 36 22 M16 x 2 28 18 38 40 43 108 (mm) Bore size (mm) Y ZZ P R S T V W X 40 8 246 1/4 37 114 11 7.5 8 27 50 10 262 3/8 43 116 11 10 9 30 63 10 280 3/8 47 120 11 12 10 37 80 13 312 1/2 57 132 11 16 13 40 100
4-M6 x 1 thread depth 10 67 4-M8 x 1.25 thread depth 10 20 0.02 8H10 depth 10 Encoder signal line Motor power line 8H10 depth 8 85 210 A (Table movement range) 78.5 (78.5) 107 10 95 Work mounting reference plane 55 Body mounting reference plane 52.5 1 D 125 8(4)-M6 x 1 thread depth 10 3(2)-8H10 depth 10 30 95 95 8(4)-6.2 C 100 () () (170) 95 95 B 110 20 (150) () () Dimensions A 329 429 529
AXT632-106A-1 AXT632-106A-2 Note) Each of the above part numbers is for two screws, which are to be ordered by 10 units. Order is accepted in 10 units.
K 11 8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46 60 70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20
RX RX RX RX RX RX RX RX (n+2)8 (n+2)9 (n+2)7 (n+2)6 (n+2)5 (n+2)4 (n+2)3 (n+2)2 Point table No. output 3 (PT2) RX(n+2)4 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 2 0 0 Point table No. output 4 (PT3) RX(n+2)5 1 1 0 0 0 0 0 3 0 0 1 4 0 0 0 0 0 0 Point table No. output 5 (PT4) RX(n+2)6 Point table No. output 6 (PT5) RX(n+2)7 1 1 1 1 1 254 1 1 0 1 255 1 1 1 1 1 1 1 Point table No. output 7 (PT6) RX(n+2)8
ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer
11) (0.5) 10 5 5 2-1 (Bleed port) 10 10 7 7 2-1 (Bleed port) M3 x 0.5 (Piping port) 28 M5 x 0.8 (Piping port) 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust center/pressure center SYJA3 40-M5 3 4 5 3 4 5 7.1 9 10 2-M3 x 0.5 (Pilot port) 1.8 10 4 A B 1.5 7 8.2 19 2-M3 x 0.5 (Pilot port) (For mounting) 2-3.2 22 3 49 2.5 (For mounting
Port size 10 8 6 12 1/8" 1/4" 3/8" 5/32" 3/16" 5/16" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure
54 56 61 74.5 84 9 10 11 13.5 15.5 19 25 25 29 35.5 45.5 55.5 15 21 27 33 37 40 2 2 2 2 2.5 2.5 1 1 1 1 1.5 1.5 5 10 10 10 15 15 11 11 12.5 15 18 21 M8 x 1.25 M8 x 1.25 M8 x 1.25 25, 50 75, 100 125, 150 175, 200 124 106 48 122 90 110 M8 x 1.25 M8 x 1.25 M8 x 1.25 140 120 56 138 100 124 M10 x 1.5 M10 x 1.5 M10 x 1.5 150 130 69 148 110 132 M10 x 1.5 M10 x 1.5 M10 x 1.5 188 160 88 185 140 166
Note 8) : Combination available for options : E1, E2, E3, E4. 1094 Direct Operated Precision Regulator Series ARP20 to ARP40 10211021Direct Operated Precision Regulator with Backflow Function Series ARP20K to ARP40K 10211021Specifications Model 10-ARP20 (K) 10-ARP30 (K) 10-ARP40 (K) 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Port size Air Fluid 1.2 MPa Proof pressure 0.7 MPa Maximum operating pressure
Note 8) : Combination available for options : E1, E2, E3, E4. 1094 Direct Operated Precision Regulator Series ARP20 to ARP40 10211021Direct Operated Precision Regulator with Backflow Function Series ARP20K to ARP40K 10211021Specifications Model 10-ARP20 (K) 10-ARP30 (K) 10-ARP40 (K) 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Port size Air Fluid 1.2 MPa Proof pressure 0.7 MPa Maximum operating pressure
0.03 10 10 15 10 5 0.05 0.03 JIS Symbol How to Order 01 VR320 0 01 Port size Precautions Rc 1 8 NPT N01 1 8 Be sure to read before handling.
A Unused A Unused A Unused A Unused A Unused A B A B A B A B A B A A A B A B A B A A A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 0 0 1 2 3 4 5 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System ADDRESS NO. STATION NO.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
3 I.D. 10.8 x 2.4 O-ring JIS B2401-4D-P11 FPM 4 Series FQ1 Dimensions Bracket 32 V-band support 2.3 75 (25) 50 100 (80) 75 70 70 30 50 10 92 7 2-A 10 108 R3.5 R8 127 (60) R25 120 109 Part number A Applicable bore size Rc 1 Rc 3/4 Rc 1/2 BP-13S BP-14S BP-15S 34.5 27.5 22 120 50 AIR VENT 10 G1/4 10 92 7 R3.5 2-Rc P 102 (43) A I N INLET OUTLET B (108) Intermediate holder Note) Installed only