D-X Individual -X 261
(Only the auto switch mounting brackets are assembled before shipment.) * The D-Y59A, Y69A, Y7P, Y7lW, Z7l, Z80 cannot be mounted on the CP96 series.
10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 84 90 98 116 126 146 159 170 204 215 16
RUN UP SET P-ON READ DOWN STOP 105.5 M5 x 0.8 x 5 (Sensor pressure port) External sensor type 123 100.5 70 M3 x 0.5 x 9.5 48 6 (Sensor breathing port) PRESSURE OUT CONTOROLLER 45 RUN 4 3 2 1 CH kPa 4 3 2 1 SW D-IN RUN UP SET P-ON READ DOWN STOP Option Panel mount adapter Panel fitting dimensions 65 or more 45 +0.5 +0.2 2 x M3 x 8 47.4 55 12 62 15 65 or more Protective cover Applicable panel
8 y e !0 P1(11) port u R(4) Exhaust port r !5 o !7 A(2) port P2(12) port w !2 !6 !4 !
A . 8-1 8.1 . 8-1 8.2 . 8-1 8.3 . 8-1 8.4 . 8-1 8.5 . 8-2 9 C . 9-1 9.1 . 9-1 9.2 . 9-1 10 L . 10-1 10.1 . 10-1 10.2 . 10-1 10.3 . 10-2 10.4 . 10-2 11 R . 11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 12 T . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 12.4 . 12-3 12.5 . 12-4 13 V . 13-1 13.1 . 13-1 13.2 . 13-1 13.3 . 13-2 14 . 14-1 14.1 . 14-1 IDFA60/70/80/90 Series
System error Brown DC(+) Internal data error 12 to 24 VDC + Black OUT Load Internal data error Blue DC() 16-2-9 10 Series ZSE30/ISE30 Dimensions 20 0.1 2-M3 x 0.5 Thread depth 4 Lead wire with connector 30 9.5 25 8 3.6 M5 x 0.8 MPa PRESSURE 20 0.1 10 SMC OUT Width across flats 12 SET 1.5 01: R 1/8 T1: NPT 1/8 A A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA
(The power supply connector is provided.) 2 The conversion fitting (R3/8 male thread) is provided.
H O W T O O R D E R (N)VM400 A C T U AT O R O N LY P A R T N O.
Removing Loosen clamp ring (1), and separate the multiconnector into two parts, multiconnector into two parts, socket side and plug side. (1) Clamping ring K (3) Case B M D H Insertion and removal of tube D + Driver (5) Barb (6) Clamp bolt (3) Case (2) Stopper Connection 1.
If they enter the inside of products, they could cause products to malfunction, lower performance or damage the element. d.
(no condensation) Temperature characteristics 5%F.S. max. (0 to 90 C, 25 C reference) Withstand voltage 1000 VAC, for 1 minute between the external terminals and case Insulation resistance 50 M or more (at 500 VDC) between external terminals and case Standards and regulations CE, RoHS Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Materials of parts in contact with fluid SUS, NBR 4,
Converter nominal size Electrical entry of solenoid valve Through the availability of a wide range of series in terms of converter capacity and valve unit flow rate control capa63 100 160 63mm 100mm 160mm G C D Air operated Grommet Conduit DIN terminal bility, speeds as high as 200mm/s (throttle valve) can be achieved with a 80 cylinder.
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Not required (Non-lube) 50 to 1000 mm/s 50 to 700 mm/s Operating piston speed Up to 250 st: , 251 to 1000 st: , 1001 to 1500 st: , 1501 to 2000 st: +1.0 0 +1.4 0 +1.8 0 +2.2 0 Allowable stroke tolerance Both ends (Air cushion) Cushion JIS Symbol Double acting Port size G 1/8 G 1/4 G 1/4 G 3/8 G 3/8 G 1/2 G 1/2 Basic, Axial foot, Rod end flange, Head end flange, Single clevis, Double clevis
(mm) 2.5 4 6 7.5 9 12 2.18 3.48 4.57 6.99 9.56 D Black (B) White (W) MS Red (R) T Blue (BU) Burst pressure (MPa) Yellow (Y) TS0425, TS0604 VMG Green (G) Other than T00425, T0604 Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Max. operating pressure (TS0425, TS0604) Max. operating pressure (For other than TS0425, TS0604) Air Fluid Max. operating pressure (at 20C) Operating
(mm) 4 6 8 10 12 M I.D. (mm) 2.5 4 5 6.5 8 H White (W) D Black (B) Red (R) MS Blue (BU) T Yellow (Y) Green (G) VMG Air/Nitrogen gas/Water (Pure water) (1) Fluid Max. operating pressure (at 20C) 0.7 MPa (2) Min. bending radius (mm) 10 20 25 30 40 Burst pressure Refer to the burst pressure characteristics curve.
Cooling capacity None Nil C D N Z Analog communication Symbol 001 002 004 008 Cooling capacity DeviceNet communication 1 kW NPT fittings 2 kW Temperature range setting Circulating fluid automatic recovery 4 kW Temperature range setting 1 kW 2 kW 4 kW 8 kW Symbol L H W 8 kW 20 to 40C 20 to 90C 20 to 90C Specifications (For details, please consult our Product Specifications information.)