Hysteresis 0 to variable 7 Withstand pressure 600 kPa Detection nozzle 1.5 4 Current flow 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 2 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at
Byte0 1 Byte1 2 Byte2 3 Byte3 PROFIBUS DP Byte4 ID(14h) Byte5 ID(11h) Byte6 Header Byte7 System diag.1 Byte8 System diag.2 Byte9 System diag.3 Byte10 System diag.4 Byte11 Reserved : : Byte18 Reserved Byte19 Header Byte20 0~7 Byte21 8~9 Byte22 Reserved : : Byte27 Reserved Byte28 A Byte29 A Byte30 A Byte31 B Byte32 B Byte33 B : : Byte61 L Byte62 L Byte63 L -71No.EX-OMN0027CN-D 1 7 6 5
Flow Characteristics Air pressure 0.7 MPa (Example) To get pressure drop at 0.3 MPa of air pressure, 2000 l/min (ANR) of air flow, and model HAA22, use P = 0.0007 MPa from the table and convert P1 to 0.3 MPa.
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (KB) D-A7/A8 Auto switch KA A + Stroke B + Stroke W L S EA EB EC M J 2 x 2-OA 2 x 2-RA Both ends tapped style (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33
Solenoid Specifications Model V114-5LU Fluid Air Ambient and fluid temperature (C) 10 to 50 (No freezing) Response time (DC) (ms) ON: 5 or less OFF: 4 or less Max. operating frequency (Hz) 20 Lubrication Not required Mounting position Unrestricted Impact/Vibration resistance (m/s2) 15030 Enclosure rating Dust proof Model V114-5LU Electrical entry L shaped plug connector(L) Coil rated voltage
Specifications Model IDG-C06 IDG-C06-P Fluid Compressed air Operating conditions range Ambient temperature oC *1 -5 to 55 Inlet air pressure MPa 0.3 to 0.85 Inlet air temperature oC *1 -5 to 55 Performance criteria Outlet air atmospheric pressure dew point oC -20 Inlet air flow rate L/min (ANR) *2 12.5 Outlet air flow rate L/min (ANR) *2 10 Purge air flow rate L/min (ANR) *2 2.5 Conditions
(Allowable SW power supply range: 19.2 V to 28.8 V) Fig. a Fig. b Summary of Product elements Double Single Double Double Double Single Double Double No. 0 2 4 6 Side A No. 5 Side A 0 2 3 5 Station Station 1 2 3 4 1 2 3 4 6 No. 1 3 5 7 Side B No. 1 4 6 Side B R O I PROCESS FIELD BUS F R P Voltage drop of max.1 V B U S PWR(V) RUN DIA BF H L H L ADDRESS + EX250 Free EX250 DIA BF PWR(V) RUN
, N2, Ar, CO2 Air, N2 Dry air, N2 Digital Digital Digital Digital Digital 0.2 to 10 L/min 0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 1 to 10 L/min 50 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 0 to 0.5 L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 1 to 1 L/min 3 to 3 L/min 5 to 500 L/min 2 to 200 L/min 5 to 50 L/min 150 to 3000 L/min 10 to 1000 L/min 10 to 100 L/min
Select the graph that corresponds to the imaginary stroke l. l k Imaginary stroke l = (Stroke) + k + l k: Distance between the center and end of the plate 6 (Example) 1. When using CXSJM6-10 and l = 15 mm: Imaginary stroke l = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 (6) ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 2.
Select the graph that corresponds to the imaginary stroke l. l k Imaginary stroke l = (Stroke) + k + l k: Distance between the center and end of the plate 6 (Example) 1. When using CXSJM6-10 and l = 15 mm: Imaginary stroke l = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 (6) ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 2.
upper limit Suction flow rate: 0 L/min 10 10 Particle concentration [particles/m3] Particle concentration [particles/m3] LAT Suction flow rate: 20 L/min ISO Class 5 upper limit LZ 10 10 LC3F2 Suction flow rate: 40 L/min ISO Class 4 upper limit ISO Class 4 upper limit 1000 1000 Suction flow rate: 20 L/min Suction flow rate: 50 L/min 100 100 Suction flow rate: 30 L/min 10 10 1 1 0 0.1 0.6 0.5
Use M12-4 pin socket (female) A cord. 19 - Refer to page 15 and 16 for procedures for changing the stopper bolt and switch positions and for top cover replacement instructions. 20 - 21 - 22 - p. 23 p. 24 p. 23 p. 24 p. 25 p. 26 23 - 24 - 25 - 26 - 27 - Refer to pages 32 and 33 for the weight of clamp arms.
min L/min L/min L/min Instantaneous Setting/display flow range 2 0.35 to 4.50 1.7 to 17.0 3.5 to 45.0 7 to 110 L/min L/min L/min L/min flow Min. setting/display unit 0.05 0.1 0.5 1 Flow L/min L/min L/min L/min Setting/display flow range 0 to 9 L Accumulated Flow Min. setting/display unit 1 L Pressure Rated pressure range 0 to 1 MPa Proof pressure 1.5 MPa NPN open collector output, PNP open
min 2.5 to 100 L/min 5 to 200 L/min Display flow range 0.424.0 L/min 2.0 to 120.0 L/min 4 to 240 L/min Set flow range 0.424.0 L/min 2.0 to 120.0 L/min 4 to 240 L/min Zero-cut flow *2 0.4 L/min 2.0 L/min 4 L/min Min. setting unit 0.1 L/min 0.5 L/min 1 L/min Accumulated volume per pulse (Pulse width:50ms) 0.1 L/pulse 0.5 L/pulse 1 L/pulse Operating Fluid temperature *3 0 to 85oC (No condensation
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 43.00000 lb
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. DIGITAL PRESSURE SWITCH. 75.00000 lb. N59.
min L/min L/min L/min L/min Instantaneous Setting/display flow range 1 2 0.5 to 10.5 2.5 to 52.5 5 to 105 10 to 210 25 to 525 L/min L/min L/min L/min L/min flow Min. setting/display unit 0.1 0.5 1.0 2.0 5.0 Flow L/min L/min L/min L/min L/min Setting/display flow range 0 to 9 L Accumulated Flow Min. setting/display unit 1 L Reference condition 3 Standard condition, Normal condition 4 Pressure
M 25 10 to 50, 75, 100 104.5 12 CC 28 10 to 50, 75, 100 124 12 L FT FX B + Stroke FZ FX (Dimensions except A and L are same as rod side flange style.)
mm/s 10 10 ISO Class 8 10 10 0 L/min (ANR) ISO Class 7 ISO Class 7 10 10 Particle concentration [particles/m3] Particle concentration [particles/m3] ISO Class 6 ISO Class 6 10 10 0 L/min (ANR) 50 L/min (ANR) ISO Class 5 ISO Class 5 10 10 1000 1000 20 L/min (ANR) ISO Class 4 ISO Class 4 100 100 70 L/min (ANR) 30 L/min (ANR) 10 10 1 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.1 0.2 0.3 0.4 0.5 0.6 Particle