SMC Corporation of America
Elite Part Number Search
Search Results "ISE20CH-T-P-N02L-WA3"

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Base Mounted Wiring: 01T1 (Plug-in w/Terminal Block, One-piece Junction Cover), Stations: 10 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 02 (1/4), Thread: T (NPTF)

Series: LEFB (Belt Drive), Size: 40, Motor Mounting Position: U (Bottom Mounting Type), AC Servo Motor: T8 (400W Output, Absolute Encoder), Lead: S, Stroke: 2000mm, Motor Option: None, Auto Switch Compatibility: None, Positioning Hole: Housing B, Bottom, Cable: R (Robotic Flexible Cable), Cable Length: 5 (5m), Driver: P2 (LECSN2-T-P, 200~240V, Absolute, PROFINET Card), I/O Connector: 1 (1.5m

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate

Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 6 (12VDC), Lead Wire: DO (DIN Connector w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: T (NPTF)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Series: KQ2, Model: T (Male Branch Tee), Applicable Tubing O.D.: 06 (ø6), Port Size/Applicable Tubing O.D.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: A (Brass), Sealant: P (Face Seal), Release Button: 1 (Oval Type)

This is a legacy product, and replaced byISE20CH-T-P-02-W ISE40/50/60 PRESSURE SWITCH. SWITCH ASSEMBLY. INSTRUMENTATION. ISE40/50/60 1/4 PT VERSION. .30130 lb. DA.

Model: 50 (Side Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Stations: 2 Stations, P,E Port Location: B (Both Sides), A,B Port Size: KC8 (ø8 One-touch Fitting, Metric, Replaceable), Thread: T (NPTF)

Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 6 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8), Thread: T (NPTF)

Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: T (Terminal Block Box), Valve Stations: 4 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]

, Flexible Cable), Cable Length: A (10m), Driver Type: 92 [LECSN2-T EtherNet/IPâ„¢ (Absolute Encoder) 200V to 240V], I/O Connector: 1 (1.5m)